IBM Support

PM75560: IEC141I 013-E1 DURING EXTRACT FROM IMAGE COPY ON TAPE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Client is trying to extract from DB2 Image copies on tape using
    BMC Unload.
    They receive the following error:
    IEC141I
    013-E1,IFG0196L,@@MDB2EX,MDB2EXTR,PSTC,6A17,504635,PRD.VANIMG.SQ
    .DB2P.TADBE.G4220V00
    They report that they have a BMC parameter USELARGEBLK set to
    Yes:
    USELARGEBLK=YES
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Optim/z v710 users who are attempting to Extract/Archive *
    * from Imagecopy                                               *
    * (using an Unload utility) and the ImageCopy is a Tape        *
    * dataset with a blocksize                                     *
    * greater than 32760.                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The client attempted to Extract/Archive from an ImageCopy on *
    * Tape using an Unload utility. The ImageCopy dataset had a    *
    * block size > 32760. The extract job abended with the         *
    * following error message:                                     *
    * IEC141I                                                      *
    * 013-E1,IFG0196L,@@MDB2EX,MDB2EXTR,PSTC,6A17,504635,PRD.VANIM *
    * G.SQ.DB2P.TADBE.G4220V00                                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply the provided fix.                                      *
    ****************************************************************
    When there are Imagecopy datasets (on Tape) that are created
    with Blocksize > 32760, Optim might fail during Extract/Archive
    process in some cases, when there are Imagecopies of multiple
    tables on the same tape.
    

Problem conclusion

  • When Imagecopies of Mutliple Tables are on the same Tape, Optim
    will attempt to reposition to the next Imagecopy without
    deallocating the Tape volume. During this process, Optim did not
    use the right DCB parameters to support LBI. Optim code has been
    modified to address this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM75560

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-22

  • Closed date

    2012-12-06

  • Last modified date

    2013-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FOPCFPMN FOPMAIN  FOPMDDDL FOPMCOFN FOPMMJBS FOPHSTM  FOP9APIM
    FOPMDXTR FOPMCMMN FOPMEMAI FOPMMUNU FOPMAMAI FOPZFBMN FOPMCOLP
    FOPMCENU FOPMSELM FOPMCBMN FOPVOU   FOPMARCN FOPMIXMM FOPZMAIN
    FOPIO    FOPZFMMN FOP1ODRV FOPMUXIM FOPMADDE FOPOMN   FOPMMUTL
    FOPMMCMR FOPMECMN FOPMDPRC FOPMCMAI FOP1OSFN FOPMDBMN FOP4IPMN
    FOP4TRCE
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • R710 PSY UK90093

       UP12/12/11 P F212