A fix is available
APAR status
Closed as program error.
Error description
WMQ V710 ABEND138 occurs when MQ tries to connect to an application CF structure that's full.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: Abend 138-090B0003 is issued when * * connecting to a CF structure, followed * * by abnormal queue manager termination * * 6C6 with REASON=00C510AB. * **************************************************************** * RECOMMENDATION: * **************************************************************** During startup the queue manager connects to each application structure, obtaining an exclusive ENQ for each. If an error occurs during CSQECONN processing after it has successfully connected using IXLCONN (for example, if CSQECLHI fails to create a list header interest map due to the structure being full) the structure is disconnected but the ENQ is not released. The next time an attempt is made to connect to that structure, a request is made for the ENQ, however because it is already held the structure task will abend 138-090B0003. The abnormal termination of the structure task then causes the queue manager to terminate 6C6 with REASON=00C510AB.
Problem conclusion
When CSQEOPEN is called to connect to an application structure during queue manager startup, it will now correctly release the ENQ it obtained if CSQECONN returns a failure return code after IXLCONN had connected to the structure. 100Y CSQEOPEN
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM72762
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-09-12
Closed date
2012-11-28
Last modified date
2013-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK83813
Modules/Macros
CSQEOPEN
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UK83813
UP13/01/16 P F301
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: