IBM Support

PM72064: Retrieve SQL fails for a column of type TIMESTAMP with error SQL type ?UNKNOWN?

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:
    - Operating System: Microsoft Windows XP
      - Product name: Rational Business Developer 8.0.1.3
      - DB2 z/VM 7.3
    
    Description of problem:
    Retrieve SQL fails for a column of type TIMESTAMP with error SQL
    type ?UNKNOWN?
    
    Steps to reproduce:
    1. Connect to DB2 z/VM from Rational Business Developer.
    2. Have a table on your DB2 z/VM containing a table with a
    column of type TIMESTAMP
    3. Run Retrieve SQL against the DB2 z/VM
    Expected Result:
    Fields for all columns in the table are generated
    Actual Result:
    The field for the column of type TIMESTAMP is not generated.
    
    Workaround:
    Add a field for the column of type TIMESTAMP manually, after
    using Retrieve SQL.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    In RBD8.0.1.3 or RBD 8.5 and before, EGL editor retrieve SQL
    fails for a column of type TIMESTAMP with error SQL type
    ?UNKNOWN? when database connection for DB2 z/VM.
    

Problem conclusion

  • In RBD 8.0.1.4 and future, when connected to DB2 z/VM,
    retrieve SQL will support TIMESTAMP type in the table
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM72064

  • Reported component name

    REQUISITEPRO WI

  • Reported component ID

    5724G3900

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-03

  • Closed date

    2012-10-08

  • Last modified date

    2012-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R801 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
08 October 2012