A fix is available
APAR status
Closed as program error.
Error description
HD Pointer Checker(HDPC) erroneously issues the following messages in the Concurrent Image Copy process of HPIC when RECON data sets are allocated by MDA library: FABP2608W ERROR OCCURRED IN ACCESSING OUTPUT REPOSITORY FUNC: OPEN(OUTPUT) RC: 08 RSN: 069 FABP2609W DB: HDAMDB1 PART: N / A DD: N / A REPORT: PC-HASH EVALUATION FABP2611W RECON ENTRY WAS NOT FOUND IN ITKB Then HDPC stops storing reports to the ITKB output repository.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who use the single-step HASH Check * * option in IBM IMS High performance Image * * copy (HPIC) jobs and store HDPC reports in * * the output repository of IMS Tools Knowledge * * Base (ITKB). * **************************************************************** * PROBLEM DESCRIPTION: HDPC in HPIC jobs erroneously issues * * MSGFABP2608W and MSGFABP2609W and does * * not store the HASH Evaluation report to * * an IMS Tools Knowledge Base (ITKB) * * output repository. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HDPC does not store the HASH Evaluation report to the ITKB output repository when all of the following conditions are met: - HDPC runs in the single-step HASH Check option of HPIC. - RECON data sets are allocated by using DFSMDA members. - CIC or ACIC statements are specified in the ICEIN control statement.
Problem conclusion
The FABPHEVS and FABPHEVL modules are modified to fix the errors.
Temporary fix
Comments
APAR Information
APAR number
PM72043
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-08-31
Closed date
2012-09-20
Last modified date
2012-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK81949
Modules/Macros
FABPHEVL FABPHEVS
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UK81949
UP12/09/21 P F209
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: