Error description
ABEND806 in APPC address space for module IOHEDEX2 when using IMS 12.1in a DRD environment, when transactions are defined.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS HIGH PERFORMANCE SYSGEN USERS. * **************************************************************** * PROBLEM DESCRIPTION: ABEND806 in APPC address space for * * module IOHEDEX2 when using IMS 12.1 * * in a DRD environment. * **************************************************************** * RECOMMENDATION: * **************************************************************** Module IOHEDEX2 was inadvertently omitted from the APAR enabling IMS 12.1 support.
Problem conclusion
Distribute module IOHEDEX2.
Temporary fix
Comments
APAR Information
APAR number
PM71351
Reported component name
IMS HP SYSGEN T
Reported component ID
5655F4300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-08-22
Closed date
2012-08-23
Last modified date
2012-09-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK81278
Modules/Macros
H24Q220J IOHEDEX2
Fix information
Fixed component name
IMS HP SYSGEN T
Fixed component ID
5655F4300
Applicable component levels
R220 PSY UK81278
UP12/08/24 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.