IBM Support

PM70977: CKZ78203E SUBTASK 01, DATASET SNAP, RC=X'00000008, RS=X'00000004

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error message "CKZ78203E Subtask 01, DATASET SNAP,
    RC=X'00000008, RS=X'00000004' may occur when using EMCAPI during
    the copy process.  The problem stems from the fact that the
    error is returned not just in a message but in the API call
    itself. Any API error (a 4 in this case) results in termination
    of the copy. The code will be changed to compare the API return
    with MAX-COPY-RC value and if not exceeded, copies will be
    allowed to continue. To allow copies to continue if this error
    is encountered, set MAX-COPY-RC=4 and MAX-RC=4.
    

Local fix

  • Correct the EMC copy environment to eliminate API return codes
    that exceed zero.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Error message "CKZ78203E Subtask 01,    *
    *                      DATASET SNAP, RC=X'00000008,            *
    *                      RS=X'00000004' may occur when using     *
    *                      EMCAPI during the copy process.  The    *
    *                      problem stems from the fact that the    *
    *                      error is returned not just in a message *
    *                      but in the API call itself. Any API     *
    *                      error (a 4 in this case) results in     *
    *                      termination of the copy. The code will  *
    *                      be changed to compare the API return    *
    *                      with MAX-COPY-RC value and if not       *
    *                      exceeded, copies will be allowed to     *
    *                      continue. To allow copies to continue   *
    *                      if this error is encountered, set       *
    *                      MAX-COPY-RC=4 and MAX-RC=4.             *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM70977

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-08-15

  • Closed date

    2012-09-21

  • Last modified date

    2012-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK82002

Modules/Macros

  •    CKZ00501 CKZ00782
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R310 PSY UK82002

       UP12/09/27 P F209

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: