Error description

  • Separate the Control Suite Policy Sensor Services and the IMS
    Tools Knowledge Base control statement generation to allow for
    one or the other not being installed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Database Control Suite users who want to *
    *                 build IMS Tools Knowledge Base and/or Policy *
    *                 Services control statements in database      *
    *                 parallel reorganization jobstreams.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: When parallel reorganization jobs are   *
    *                      generated by DBCS, IMS Tools Knowledge  *
    *                      Base AND Policy services control        *
    *                      statements are created regardless of    *
    *                      whether one or the other tools is       *
    *                      installed or not.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Logic was added to only generate IMS Tools Knowledge Base and
    Policy Services control statements independently of each
    other.
    
    An additional non-related fix is in this APAR to issue the
    following message during the SETUP function if an expected
    DSPSCIX0 is not in the IMS RESLIB for a SYSPLEX.
    
    IDLR559: IDLRBUIL; CC = 12, IMS release discovery failure.
    DSPURX00 SYSIN control statements displayed for diagnostic use.
    Check TSO session log for additional DBRC issued messages.
    RESLIB could be missing DSPSCIX0 exit if the RECONs are used in
    a SYSPLEX.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PM70359

  • Reported component name

    IMS DB CNTL SUI

  • Reported component ID

    5655F7600

  • Reported release

    320

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-08-06

  • Closed date

    2012-08-10

  • Last modified date

    2012-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK81000

Modules/Macros

  • IDLC0001 IDLIPR01 IDLIPR07 IDLIPR08 IDLRBUIL
    IDLR55
    

Fix information

  • Fixed component name

    IMS DB CNTL SUI

  • Fixed component ID

    5655F7600

Applicable component levels

  • R320 PSY UK81000

       UP12/08/17 P F208

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date:
22 October 2020