Error description

  • An ABEND0C4 can occur in CEXRCDPR if the recorder trace
    record is for Sync call-out. The event record 161 has been
    built with an invalid application data section by CEXRCDUT
    during the conversion process.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extentions V2.2         *
    ****************************************************************
    * PROBLEM DESCRIPTION: An Abend 0C4 can occur in CEXRCDPR if   *
    *                      the recorder trace record is for Sync   *
    *                      callout.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An Abend 0C4 can occur in CEXRCDPR if the recorder trace
    record is for Sync callout. The event record 161 has been
    build with an invalid application data section by CEXRCDUT
    during the conversion process.
    

Problem conclusion

  • Corrected CEXRCDUT to recognize the sync callout message
    that has a 4 byte application LL instead of the normal
    2 byte application LL.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM69996

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-07-31

  • Closed date

    2012-08-02

  • Last modified date

    2012-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK80783

Modules/Macros

  • CEXRCDUT
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R220 PSY UK80783

       UP12/08/04 P F208

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
22 October 2020