APAR status
Closed as program error.
Error description
If an input object within a map is larger than the page size defined for the map, a return code of 21 (Input valid but unknown data found) is generated. The map may fail to properly identify the input data resulting in unpredictable map output. The input object is not the entire data, but an individual object read in by the map as defined within a type tree.
Local fix
WTXCQ - WTX00041115 TR / TR Circumvention: Increase the page size of the map to be larger than an individual input object.
Problem summary
Users Affected: WebSphere Transformation Extender customers using 8.4.0.3 service pack who observe the unexpected input validation error that depends on the page size Problem Description: Product was not seeing correct data when validating objects larger than a page. Platforms Affected: All
Problem conclusion
The code that moves some of the data from the end of the page to the beginning and then fills the remaining page with new data, was incorrect. It has now been corrected. Delivered in: 8.4.0.4
Temporary fix
Comments
APAR Information
APAR number
PM69217
Reported component name
WEBSPHERE LAUNC
Reported component ID
5724M4011
Reported release
840
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-07-19
Closed date
2012-08-13
Last modified date
2013-01-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE LAUNC
Fixed component ID
5724M4011
Applicable component levels
R840 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]