A fix is available
APAR status
Closed as program error.
Error description
MSG FPQ0002E WITH FEEDBACK: 00060017 D9C9C908 00000002 INDICAT- ING VSAM ERROR OF DUPLICATE KEY OR BAD LOAD SEQUENCE. Since we are not loading it must be Duplicate key. It appears this all this happened after they deleted some current report, that might have changed the number of history generations.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Tools Base 1.1 - component ITKB * * and Policy Services. * **************************************************************** * PROBLEM DESCRIPTION: FPQ0002E with FEEDBACK: 00060017 * * D9C9C908 00000002 shows, indicating * * VSAM error of duplicate key or bad * * load sequence. * **************************************************************** * RECOMMENDATION: * **************************************************************** This message shows when the current report has been deleted, then a new report is stored with seq number 1 ( because of missing current). On next report the current with seq number 1 has to be written as history, but such history report exists.
Problem conclusion
The server program has been changed to delete history reports with sequence number equal or greater than the current report.
Temporary fix
Comments
APAR Information
APAR number
PM67054
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-06-18
Closed date
2012-10-04
Last modified date
2012-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82356
Modules/Macros
FPQSIORQ
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R110 PSY UK82356
UP12/10/08 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date: