A fix is available
APAR status
Closed as program error.
Error description
Running Object Comparison Tool For z/OS V10.1 customer may get the following: . FUNCTION = ADBGAJOB, LINE nnn: If adb101nf = 'Y' & utc29 <> 'N' Then . RC = 8 . ZERRMSG = ISRZ002 ZERRSM = Novalue condition raised for variable ADB101NF ZERRLM = Error executing EXEC - now terminating . ISPD117 The initially invoked CLIST ended with a return code = 8
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of the DB2 Administration Tool for * * z/OS who manually provide DB2 release * * settings through manual modifications of * * the generated job step. * **************************************************************** * PROBLEM DESCRIPTION: When the ALTSHV or GOCSHVRS data set * * contents are modified to add, change * * or alter the release flag contents * * (i.e. ADB101NF, ADB101CM, ADB091NF, * * ADB091CM, ADB081NF and ADB081CM), * * the DB2 Administration Tool for z/OS * * does not automatically set missing * * flags. For example, if the user * * specifies only ADB101NF of 'Y', the * * subordinate flags (i.e. all the other * * release flags) should be 'Y' as well. * * This change will now automatically set * * these subordinate release flags when * * they are not also provided. This will * * make it easier for users who want to * * manually modify and provide these * * switch settings. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** Logic has been added to determine the 'highest' DB2 release switch set and to set all subordinate switches that have not been provided. Since the user can enter these flags, ADB101NF, ADB101CM, ADB091NF, ADB091CM, ADB081NF and ADB081CM manually, we now will edit them. All provided flags must be 'Y' or 'N'. If not provided, a flag will resolve as '' (nothing). The following error will be produced if any of these edits fails: Invalid value provided to >flag< = >value< One additional edit has been done as well. If you either do not provide or provide 'N' for ADB101NF AND you provide 'Y' for ADB101CM and then do not give use a value for ADB091NF, we will produce the following error: 'ADB091NF must be provided as Y or N when ADB101NF is not provided and ADB101CM is Y' This can be resolved by providing 'Y' or 'N' for ADB091NF. Since these flags can be entered by the user we will also allow the long values of YES and NO. This will not fail any edits. The flags are case sensitive.
Problem conclusion
Problem has been resolved.
Temporary fix
Comments
APAR Information
APAR number
PM66298
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-06
Closed date
2012-10-24
Last modified date
2012-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82911 UK82912
Modules/Macros
ADBGAJOB
Fix information
Fixed component name
DB2 ADMIN TOOL
Fixed component ID
568851500
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 November 2012