You are using CPSM BATCHREP either through the WUI or by a batch job. The output of your BATCHREP contains a message similar to the following: . EYUXU0203E Method failure in (XDBX) - response (02) - reason (04). . In the CMAS job log, you see an ASRA / S0C4 has occurred, with messages similar to the following: . . DFHDU0205 CMASJOB A SYSTEM DUMP FOR DUMPCODE: AP0001 , WAS SUPPRESSED BY THE DUMP TABLE OPTION FOR THIS DUMPCODE EYUXL0900I Starting Environment Recovery EYUXL0905E CMASJOB ASRA IN MOFS, OFFSET 00000D7E PSW=078D5000 960BDB4E EYUXL0905E INTC=0011 ILC=4 TXCP=00936001 SCODE=S00C4 TRAN=XDBM TASK=##### EYUXL0905E Methods=MOFS,XDBX,XDBM,XLOP EYUXL0905E BEAR=160BD5A0, OFFSET=000007D0 EYUXL0906I Registers at ABEND EYUXL0907I GPR0-GPR1 00000B43_16505020 00000003_16504978 EYUXL0907I GPR2-GPR3 00000000_00800EB0 00000000_160C07C8 EYUXL0907I GPR4-GPR5 00000000_160C17C8 00000000_001352CB EYUXL0907I GPR6-GPR7 00000000_160BD5A0 00000000_00000000 EYUXL0907I GPR8-GPR9 00000000_00000001 00000000_16504EA8 EYUXL0907I GPRA-GPRB 00000000_FFFFFFFF 00000000_00000001 EYUXL0907I GPRC-GPRD 00000000_167CCDAC 00000000_16504170 EYUXL0907I GPRE-GPRF 01FF0040_0093617B 00000002_16504AA2 EYUXL0907I ARR0-ARR3 00000000 00000000 00000000 00000000 EYUXL0907I ARR4-ARR7 00000000 00000000 00000000 00000000 EYUXL0907I ARR8-ARRB 01FF0054 00000000 01FF0054 00000000 EYUXL0907I ARRC-ARRF 00000000 00000000 00000000 00000000 EYUXL0907I FPR0-FPR1 00000000_00000000 00000000_00000000 EYUXL0907I FPR2-FPR3 00000000_00000000 00000000_00000000 EYUXL0907I FPR4-FPR5 00000000_00000000 00000000_00000000 EYUXL0907I FPR6-FPR7 00000000_00000000 00000000_00000000 EYUXL0907I FPR8-FPR9 00000000_00000000 00000000_00000000 EYUXL0907I FPRA-FPRB 00000000_00000000 00000000_00000000 EYUXL0907I FPRC-FPRD 00000000_00000000 00000000_00000000 EYUXL0907I FPRE-FPRF 00000000_00000000 00000000_00000000 EYUXL0907I FPCR 00000000 EYUXL0908I Storage At ABEND EYUXL0909I -20 005D585C 003C9240 D939D2FD D93AD939 EYUXL0909I -10 5870D8E8 18A75EA0 3CD851E0 50001EE2 EYUXL0909I +00 44A0305A D219DB86 D9381867 18875E80 EYUXL0909I +10 3CD84480 3030A77E 0001A774 00159240 EYUXL0910I EYU9XLRV Dump,CMASJOB,CMASJOB,MV30,CMAS,XDBM,#####,ASRA,EYU0MOFS, MM/DD/YYYY,HH:MM:SS EYUXL0999I XLRV Exiting Successfully . IEA794I SVC DUMP HAS CAPTURED: DUMPID=xxx REQUESTED BY JOB (CMASJOB) DUMP TITLE=EYU9XLRV Dump,CMASJOB,CMASAPPL,MVSX,CMAS, XDBM,#####,ASRA,EYU0MOFS,MM/DD/YYYY,HH:MM:SS . In the registers that are traced in the job output, general purpose register 10 (GPRA) contains negative 1, (-1), 00000000_FFFFFFFF. . Additional Keywords/Symptoms: EYU9XLRV Dump XDBM ASRA EYU0MOFS KIXREVNDB
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users * **************************************************************** * PROBLEM DESCRIPTION: You are using CPSM BATCHREP either * * through the WUI or by a batch job, to * * CREATE a CSYSDEF object. The output of * * your BATCHREP contains the following * * message: * * . * * EYUXU0203E Method failure in * * (XDBX) - response (02) - * * reason (04). * * . * * In the CMAS job log, you see abend ASRA * * (S0C4) has occurred, at offset +000D7E * * in module EYU0MOFS (MOFS - MOS Field * * Services). * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes which act as Maintenance * * point for one or more CICSplexes must be * * recycled to pick up the new code. Note * * that CMASes do not need to be brought down * * and restarted at the same time. * **************************************************************** Module EYU0MOFS is called during resource creation to con- vert attribute values from external to internal form. When testing character attributes for the special INHERIT values '*' or 'INHERIT' local variables used to determine the address and length of the value to be compared are not initialized. Abend S0C4 might occur if these variables contain residual data.
Problem conclusion
Module EYU0MOFS was modified to use the starting address and length passed in the Method Argument List when testing character attributes for special values.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PM66180
Reported component name
CICS TS Z/OS V4
Reported component ID
5655S9700
Reported release
70M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-06-05
Closed date
2012-06-14
Last modified date
2012-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK79605 UK79606
Modules/Macros
DYU0MOFS EYU0MOFS
Fix information
Fixed component name
CICS TS Z/OS V4
Fixed component ID
5655S9700
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 July 2012