Error description
v420 customer received abend0C4 in OMPE Server/Collector STC: . KO2O1385I SSN=DSN REQUEST=IDENTIFY FROM=DSNRLI RC=00000008 RS=00F30012 KO2O1407E NEAR-TERM HISTORY DATA COLLECTOR - DB2 SUBSYSTEM IS NOT ACTIVE OR IS TERMINATING (CHECKRC ) IEA794I SVC DUMP HAS CAPTURED DUMPID=100 REQUESTED BY JOB (DCOMDC) DUMP TITLE=OMEGAMON II FOR DB2 DUMP: TASK=VOL-DSN MOD=KO2EVLS3,OFFSET=000108, CODE=S0C4/00000011 KO2E3042I VOLUME ANALYSIS TERMINATED FOR DB2=DSN . Note also that the collector was indicating that this subsystem (DSN) was inactive even though it was in fact up. . Note also that even when the abend0C4-11 doesn't occur, the OMPE Server still thinks that the DB2 subsystem is down when it is actually up and the OMPE Server has to be recycled to resolve this situation. .
Local fix
To resolve, restart the OMPE Server/Collector STC.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Object Analysis * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4-11 in KO2EVLS3 when a DB2 * * subsystem is showing inactive in the * * OMPE server/collector when the * * subsystem is really up. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: OmPE abends with code 0C4 when multiple instance of the same DB2 exists. PROBLEM CONCLUSION: Code changed for recovery retry after 0C4 abend in Volume Analysis. KEYWORDS: ABEND0C4 EVLS
Problem conclusion
Code changed for recovery retry after 0C4 abend in Volume Analysis. KEYWORDS: ABEND0C4 EVLS
Temporary fix
Comments
APAR Information
APAR number
PM65348
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-23
Closed date
2012-09-20
Last modified date
2012-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK81959
Modules/Macros
KO2EVLAB KO2EVLSA KO2EVLSK KO2EVLS3
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R511 PSY UK81959
UP12/09/23 P F209
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 October 2012