A fix is available
APAR status
Closed as program error.
Error description
HP Image Copy terminates with ABEND U4000 with TOSI message FOI571W when TOIAUTO_Q=Y is requested. Because HP Image Copy request TOSI TYPE-2 disconnect command without obtaining request buffer of TOSI.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 2 users ( FMID=H1J0420 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes following 2 problems * * of HP Image Copy when using IMS Tools * * Online System Interface of Tools Base: * * * * 1. When UPDATE DB STOP(QUIESCE) command * * is used by TOIAUTO_Q=Y, HP Image * * Copy terminates with * * message FABJ4608E ( MSGFABJ4608E ) * * and ABEND U4000 ( ABENDU4000 ). * * * * 2. When TOIAUTO=Y is requested in HP * * Image Copy Advanced Image Copy * * function and IMS online region * * program is terminated before /STA * * command is issued from HP Image * * Copy, HP Image Copy terminates with * * message FABJ4603E ( MSGFABJ4603E ) * * and ABEND U4000 ( ABENDU4000 ). * * * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes following 2 problems of HP Image Copy when using IMS Tools Online System Interface of Tools Base: 1. When IMS UPDATE DB STOP(QUIESCE) command is used by TOIAUTO_Q=Y, HP Image Copy terminates with ABEND U4000 ( ABENDU4000 ) RC=08 ( RC08 ) by following symptom: - Issue FABJ4608E ( MSGFABJ4608E ) with RC=00000004, RSN=00000701 ( RC00000004 RSN00000701 ). HP Image Copy tries to issue UPDATE DB STOP(QUIESCE) command in the termination process in case UPDATE DB STOP(QUIESCE) command has not been processed. But if all DB has been already released DB QUIESCE status, unnecessary IMS Tools Online System Interface call is done in HP Image Copy and IMS Tools Online System Interface returns error. HP Image Copy should not issue unnecessary IMS Tools Online System Interface call in the termination process, when IMS command has been done successfully. 2. When TOIAUTO=Y is requested in HP Image Copy Advanced Image Copy function and IMS online region program is terminated before /STA command is issued from HP Image Copy, HP Image Copy terminates with ABEND U4000 ( ABENDU4000 ) RC=08 ( RC08 ) by following symptom: - Issue FABJ4603E ( MSGFABJ4603E ) with RC=00000012, RSN=00000201 ( RC00000012 RSN00000201 ). If IMS Online region is terminated during HP Image Copy process, IMS command can not be processed, so HP Image Copy should bypass IMS command process through the IMS Tools Online System Interface. When the IMS Online region is not active, IMS Tools Online System Interface checks it in the initialization process and returns error reason to HP Image Copy. Then HP Image Copy does not issue the termination request call of IMS Tools Online System Interface and tries to continue IMS command request for next Database. HP Image Copy should issue the termination request of IMS Tools Online System Interface if its error reason at the initialization process is that IMS Online region is not active.
Problem conclusion
FABJTOI2 has been modified not to issue unnecessary IMS Tools Online System Interface call in the termination process. FABJSTA has been modified to issue the termination call of IMS Tools Online System Interface if the IMS Online region is not available.
Temporary fix
Comments
APAR Information
APAR number
PM62697
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-04-18
Closed date
2012-04-27
Last modified date
2012-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK78328
Modules/Macros
FABJSTA FABJTOI2
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R420 PSY UK78328
UP12/05/02 P F205
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: