IBM Support

PM62612: CICS RESOURCE DEFINITION CHANGES REPORT SHOWS INCORRECT TIME IN THE REPORT HEADER.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CICS Resource Definition Changes Report shows incorrect time in
    the report header. Report shows one hour ahead:
    
    ----------------------------------------------------------------
    12012/03/05 16:57    CICS Configuration Manager V2.1      Page 2
                ^^^^^              Batch Utility
             Wrong time!!!
    
                         CICS Resource Definition Changes Report
                              Resource View, Resource Level
                      Sorted by CONFIGURATION,DATE,NAME,TYPE,GROUP
    ----------------------------------------------------------------
    

Local fix

  • Run with this card to obtain the CICS Resource Definition
    Modify the parameters to suit your time zone.
    
    //CEEOPTS  DD *
           ENVAR("TZ=GMT-1GMT-0,M3.5.0/02:00:00,M10.5.0/03:00:00")
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS Configuration Manager.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The displayed time in the CCVBMAIN      *
    *                      report heading is incorrect.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The CCVBMAIN utility program displays an incorrect time in its
    report heading that does not match the time in the JES job log
    when the utility was run.
    The report heading date/time routine did not correctly handle
    the Language Environment (LE) timezone environment variable
    that can be set via the PARMLIB member CEEPRMnn ENVAR setting,
    or a SETCEE CEEDOPT,ENVAR(TZ=...) operator command.
    

Problem conclusion

  • The CCVBMAIN utility has been corrected to base the local
    date/time solely on the z/OS CVT (Communications Vector
    Table) settings.
    210Y
    CCVBMAIN
    CCVIBM$0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM62612

  • Reported component name

    CICS CONFIG MGR

  • Reported component ID

    5697P0900

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-17

  • Closed date

    2012-04-27

  • Last modified date

    2012-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK78334

Modules/Macros

  •    CCVBMAIN CCVIBM$0
    

Fix information

  • Fixed component name

    CICS CONFIG MGR

  • Fixed component ID

    5697P0900

Applicable component levels

  • R210 PSY UK78334

       UP12/05/02 P F205

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2L7A","label":"CICS Configuration Manager for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]