IBM Support

PM61077: RECURSIVE S0C4 ABEND IN ALZBRMIO AT OFFSET X'618'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IMS PI sets an ESTAE exit in ALZBRMIO to catch errors when input
    files are OPENed. However, it is also possible to drive this
    ESTAE routine if a GETMAIN storage request abends.
    Once invoked in this manner,  the ESTAE recovery routine gets an
    ABENDS0C4 abend which re-drives the ESTAE again creating an
    indefinite loop..
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Problem Investigator V2.2       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Recursive S0C4 abend in ALZBRMIO at     *
    *                      offset X'618'                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Recursive S0C4 abend in ALZBRMIO at offset X'618'
    IMS PI sets an ESTAE exit in ALZBRMIO to catch errors when input
    files are OPENed. However, it is also possible to drive this
    ESTAE routine if a GETMAIN storage request abends.
    Once invoked in this manner, the ESTAE recovery routine gets a
    S0C4 abend which re-drives the ESTAE again creating an
    indefinite loop.
    

Problem conclusion

  • Ensure that the ESTAE routine is only invoked for file OPEN
    errors.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM61077

  • Reported component name

    IMS PROBLEM INV

  • Reported component ID

    5655K5000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-03-23

  • Closed date

    2012-04-24

  • Last modified date

    2012-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK78237

Modules/Macros

  • ALZBRMIO
    

Fix information

  • Fixed component name

    IMS PROBLEM INV

  • Fixed component ID

    5655K5000

Applicable component levels

  • R220 PSY UK78237

       UP12/05/02 P F205

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: