IBM Support

PM59902: MSG ASMA013S IS ISSUED WHEN ARETRY PARAMETER VALUE IS LONGER THAN 450 CHARACTERS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When low key value or high key value specified in ARETRY
    parameter of AREADEF control statement is longer than 450
    characters, the message ASMA013S is issued and the SRG ends
    with RC=8 .
    Even if the ARETRY parameter value is divided by AREXT
    parameter, the message ASMA013S is issued when the combination
    of ARETRY parameter values is longer than 450 characters.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Sequential Randomizer       *
    *                 Generator for OS/390 Release 1               *
    *                 (FMID=H1J1110) who uses DEDB randomizers     *
    *                 generated by SRG.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Various errors occur when extremely     *
    *                      long key values are specified for the   *
    *                      ARETRY parameter of the AREADEF control *
    *                      statement.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    In the following descriptions, #CHAR represents the total number
    of characters in the key specification of ARETRY parameter.
    #CHAR includes the character that is specified by CVCHAR, but it
    does not include the character specified by DELCHAR.
    When the AREXT parameter is specified, #CHAR is the total sum of
    #CHAR for the lower bound value or the upper bound value over
    all sub-key value pairs.
    
    For the detail of #CHAR, refer to the section "C.1.3 Work
    Storage Size" in the IMS Sequential Randomizer Generator for
    OS/390 User's Guide.
    (http://publib.boulder.ibm.com/cgi-bin/bookmgr/BOOKS/faboga10/C.
    1.3?SHELF=&DT=20021031170258)
    For the format of the AREXT parameter, refer to the section
    "2.5.1.5 AREADEF Control Statement" in the IMS Sequential
    Randomizer Generator for OS/390 User's Guide.
    (http://publib.boulder.ibm.com/cgi-bin/bookmgr/BOOKS/faboga10/2.
    5.1.5?SHELF=&DT=20021031170258)
    
    1. When #CHAR of the ARETRY parameter of an AREADEF control
    statement is larger than 450, the message ASMA013S is issued and
    the SRG ends with RC=8.
    
    2. When #CHAR is larger than 256, and two or more
    AREADEF control statements are specified, the messages XPRI-002
    and FABO0116A are issued and the SRG ends with RC=8.
    
    3. When #CHAR is larger than 256, and two or more key ranges are
    specified by an ARETRY parameter, the messages XPRI-001 and
    FABO0116A are issued and the SRG ends with RC=8.
    
    4. The number of key ranges that can be specified on an ARETRY
    parameter is bounded by the following condition:
       (*) Twice the number of bytes of actual key value multiplied
    by the number of ARETRY key range pairs must be less than 32759.
    
      For example:
        (1) If the length of the key is 5 bytes, up to 3,000 key
            range pairs can be specified in an ARETRY parameter.
        (2) If the length of the key is 25 bytes, up to 655 key
            range pairs can be specified in an ARETRY parameter.
        (3) If the length of the key is 255 bytes, up to 64 key
            range pairs can be specified in an ARETRY parameter.
    
    However, this upper bound limit is not checked by SRG and,
    when the limit is exceeded,  only a part of input keys are used
    for creating the equation table. As a result, the generated
    randomizer might not satisfy the specified optimization criteria
    for the CI capacity and the number of maximum synonyms.
    

Problem conclusion

  • for the CI capacity and the number of maximum synonyms.
    PROBLEM CONCLUSION:Ø
    The macro FABOARCK has been modified to add ACTR instruction to
    reset the conditional assembly loop counter.
    
    The macro FABOARE has been modified to punch the correct ARETRY
    parameter value when the #CHAR of the lower bound key or the
    upper bound key of the key range is larger than 480.
    
    The macro FABOI has been modified to compare the lower bound key
    with the upper bound key correctly.
    
    The module FABOGNSR has been modified to print the DEDB master
    table report correctly when the #CHAR of the lower bound key or
    the upper bound key of the key range is larger than 495.
    
    The module FABOSRR1 has been modified to print the lower and
    upper bound key values of ranges correctly when two or more
    AREADEF control statements are specified and the #CHAR of the
    lower bound key or the upper bound key of the key range is
    larger than 256.
    
    The new parameter KEYRNG has been added to the AREADEF control
    statement. The KEYRNG parameter is a replacement of the ARETRY
    parameter and functions as same as the
    ARETRY parameter, except that the maximum key length and the
    maximum allowable number of key ranges are extended so that
    up to 3,000 key ranges of a key that has the length of 255
    in number of characters (#CHAR) can be specified.
    
    All problem fixes described above for the ARETRY parameter
    are applied to the KEYRNG parameter also.
    
    The module FABOMAIN and FABOCOMP have been modified to support
    the KEYRNG parameter.
    
    The use of KEYRNG parameter is recommended for new SRG JCLs.
    However, the ARETRY parameter is also supported
    for the compatibility with existing SRG JCLs and existing
    SRG DEDB randomizers.
    
    SRG does not stop its processing even if the ARETRY parameter
    is specified and twice the number of bytes of actual key value
    multiplied by the number of ARETRY key range pairs exceeds
    32,759, in which case the new warning message, FABO0212W, is
    issued, the SRG processing continues, and the job ends with a
    return code of 4.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS Sequential Randomizer Generator for OS/390 User's Guide
    (SC27-0926-01) should be changed as follows:
    
    Descriptions for the ARETRY parameter in the following sections
    in the User's Guide also apply to the new KEYRNG parameter:
    - Section 2.5.1.5 AREADEF Control Statement
    - Section G.5 SRG Messages
    - Section G.6 SRG Control Statement Messages
    - Section 2.7.5 DEDB Master Table Report
    - Section C.1.3 Work Storage Size
    - Section A.2 AREADEF Control Statement (Table 9)
    - Section 3.3 Example 3: Generating SR for a DEDB Database
    - Section 3.4 Example 4: Re-creating a DEDB Area Equation Table
    - 3.5 Example 5: Adding a DEDB Area Equation Table
    
    The following messages are added:
    
    FABO0212W THE NUMBER OF ARETRY KEY RANGES EXCEEDED THE ALLOWABLE
              MAXIMUM FOR AREA: xxxxxxxx.  USE THE KEYRNG PARAMETER
    Explanation: The number of the ARETRY key ranges that is
    specified in the AREADEF control statement for the indicated
    area exceeded the allowable maximum for the length of the input
    key in number of characters.
    
    The internal counter of the ARETRY
    key range table overflow and some key ranges are not used.
    As a result, those input keys that are within the discarded key
    ranges are not processed when SRG builds the equation table for
    the area and when SRG simulates randomizer calls for the area.
    
    System Action: SRG continues processing, generates the SRT
    source member for the area, creates or updates the SRR source
    member with the correct master table entries for the area and
    ends with RC=4.
    
    Note: SRG does not stop its processing for the compatibility
    with existing SRG JCLs and existing SRG DEDB randomizers.
    
    Programmer Response: Unless you have a compatibility issue with
    the existing randomizer that has been generated in past jobs,
    consider replacing the AREATRY parameter with the KEYRNG
    parameter.
    
    FABO9000A (AREADEF-018) ** KEYRNG PARAMETER CANNOT BE
              SPECIFIED WITH ARETRY PARAMETER
    Explanation: The KEYRNG parameter and the ARETRY parameter
    of the AREADEF control statement are mutually exclusive.
    System Action: SRG issues the FABO0107A message and ends
    the job with RC=8.
    Programmer Response: Specify one of these parameter and
    rerun SRG.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM59902

  • Reported component name

    IMS SEQ RANDOMI

  • Reported component ID

    5655E1100

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-03-07

  • Closed date

    2012-04-02

  • Last modified date

    2012-06-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK77593

Modules/Macros

  • COMMENTS:
    MODULES/MACROS:  ØFABOARCK FABOARE  FABOCOMP FABOGNSR FABOI
    FABOMAIN FABOSRR1
    

Publications Referenced
SC27092601    

Fix information

  • Fixed component name

    IMS SEQ RANDOMI

  • Fixed component ID

    5655E1100

Applicable component levels

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEQ76","label":"IBM IMS Sequential Randomizer Generator for OS\/390"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]