Fixes are available
APAR status
Closed as program error.
Error description
In Rhapsody, for a Statechart junction connector that has two incoming transitions, and one outgoing transition, only one of the pathways has the correct guard generated for it.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** In cases where a single trigger triggers multiple transitions, the code that is generated ignores any guards that appear after a junction connector, diagram connector, or enter-exit point connector that follow any of the transitions.
Problem conclusion
Fixed in version 8.0. To preserve the previous code generation behavior for pre-8.0 models, a property called CG::Statechart::UsePre80StatechartCG was added to the backward compatibility settings for C, C++, and Java with a value of True.
Temporary fix
Comments
APAR Information
APAR number
PM58445
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-17
Closed date
2012-09-21
Last modified date
2012-09-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R761 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1","Line of Business":{"code":"LOB02","label":"AI Applications"}}]
Document Information
Modified date:
28 October 2021