IBM Support

PM58049: LAST NTH SEQUENTIAL DATASET REMAINS ALLOCATED TO OMPE AFTER NTH SHUTDOWN MSGIEC143I ABENDS0213 RC9C

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IEC143I
    213-9C,IFG0193A,OMXEO2,OMXEO2,SYS00035,1AE3,SMGX28,SYSP.OMEGA.SA
    7F.DB2Z.RKD2SQ02
    FPEV0165I  MSTR INSTANCE FOR DB2 SUBSYSTEM DB2S IS STOPPING
    KO2S0500E OSNP SDUMPx Failure. RC: 00000208
    KO2O1352I DB2S> -STOP TRACE(PERFM)  TNO(12  )
    IEA794I SVC DUMP HAS CAPTURED:  133
    KO2S0508E OSNP LMOD: #UNKNOWN, CSECT: SNAPDATA, OFFSET:   0000
    KO2O1352I DB2S> -STOP TRACE(MON)  TNO(11  )
    DUMPID=004 REQUESTED BY JOB (OMXEO2  )
    DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMXEO2  ,
                LMOD=#UNKNOWN#L, CSECT=SNAPDATA, OFFSET=  0000
    .
    Symptom             Description
    -------             -----------
    RIDS/IGC0001I#L     Load module name: IGC0001I
    RIDS/#UNKNOWN       Csect name: #UNKNOWN
    AB/S0213            System abend code: 0213
    PRCS/0000009C       Abend reason code: 0000009C
    REGS/0E76E          Register/PSW difference for R0E: 76E
    REGS/C22AC          Register/PSW difference for R0C:-22AC
    .
    PSW: 075C1000 80E7CC52   Instruction length: 02   Interrupt
    code: 000D
    Failing instruction text: 4100302C 0A0D010D A7E50126
    .
    Registers 0-7
    GR: 00E7CF10 A4213000 00027E30 00E7CEE4  009A0410 009A07A4
    009A074C 009A07A4
    Registers 8-15
    GR: 009A076C 0099FEC0 80E7E182 00E7ED2A  80E7EEFE 7F509D20
    80E7C4E4 0000009C
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Near Term History                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: OMEGAMON II FOR DB2: COMPID=5655OPE00,  *
    *                      JOB=xxxxxxxx, LMOD=#UNKNOWN#L,          *
    *                      CSECT=SNAPDATA. IEC143I 213-9C.         *
    *                      IEC988I.  Last NTH sequential dataset   *
    *                      still allocated after stopping NTH.     *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    Multiple NTH collectors can try to close sequential datasets
    simultaneously, causing S213-9C abend(s).  FREE=CLOSE was not
    honored.
    
    PROBLEM CONCLUSION:
    Ensure unique closing and freeing of NTH collection sequential
    datasets.
    

Problem conclusion

  • Ensure unique closing and freeing of NTH collection sequential
    datasets.
    
    KEYWORDS : IEC988I NTH NEAR TERM HISTORY S213-9C ABEND
               SEQUENTIAL DATASETS
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM58049

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-13

  • Closed date

    2012-06-11

  • Last modified date

    2013-08-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK79474 UK79475

Modules/Macros

  • KO2$QIOB KO2CNSRB KO2DCS2B KO2DDSBA KO2DDSBK
    KO2DDSBS KO2DDSB2 KO2DMSCA KO2DMSCS KO2DMSC2 KO2DTHDA KO2DTHDS
    KO2DTHD2 KO2HDTIB KO2HDTPB KO2HTRMB KO2HWLMB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R420 PSY UK79474

       UP12/06/13 P F206

  • R510 PSY UK79475

       UP12/06/13 P F206

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
20 August 2013