Error description
Mismatch detection may occur when multiple indexes with different names that satisfy primary key and or unique rule constraints are present. When cloning tool produces the DDL for these indexes, whichever index gets created first gets the UNIQUERULE P or C designation causing a mismatch detection.
Local fix
Create DB2 objects outside of DB2 Cloning Tool. . Steps to creating outside of DB Cloning Tool: 1) Generate DDL from DB2 Admin Tool 2) Edit the Generated DDL (Add a DROP DATABASE statement at the beginning of the generated DDL) 3) Construct the DB2 Cloning Tool COPY statement to read and execute the external DDL dataset (Certain parameters are required to allow the DB2 Cloning Tool to read an external DDL dataset for input into the cloning process. 4) Construct the DB2 Cloning Tool COPY statement to disable the process DDL parameter and create the cloned copies of the source data via ADRDSSU (Change the parameters in the DB2 Cloning Tool COPY statement in order to create the clone the target.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Cloning Tool. * **************************************************************** * PROBLEM DESCRIPTION: Mismatch detection may occur when * * multiple indexes with different names * * that satisfy primary key and or unique * * rule constraints are present. When * * cloning tool produces the DDL for these * * indexes, whichever index gets created * * first gets the UNIQUERULE P or C * * designation causing a mismatch * * detection. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM57865
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-09
Closed date
2012-02-27
Last modified date
2012-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CKZGASM2
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R310 PSY UK76584
UP12/03/02 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 February 2021