Environment: z/OS Product name: IBM? Rational? Business Developer Program Version : 8.0.1.3 Description. A compilation error is thrown from COBOL source, runtime with Channel generation where the linkage pgmname includes an asterisk within the applicable name. Example linkage line : ?localCall pgmName='CH*' linkType='CICSLINK' parmForm='CHANNEL' pgmType='EGL' refreshScreen='NO'/? Generation of the program will produce a compile error eg: 'IGYPS0083-E An alphanumeric literal with a length of zero was found. A length of one character was assumed. ' and such as the following statement in COBOL source: MOVE '' TO CHANNEL-NAME When specified with the full name: ?localCall pgmName='CHAAA' linkType='CICSLINK' parmForm='CHANNEL' pgmType='EGL' refreshScreen='NO'/? the code will successfully compile and this statement is represented as: MOVE 'CHAAA' TO CHANNEL-NAME
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The usage of a wildcard character in the linkage table when using a channel interface was not correctly calculating the alias to use, resulting in no alias being specified, causing a COBOL compile error.
Problem conclusion
Software has been updated and a fixtest is available.
Temporary fix
Comments
APAR Information
APAR number
PM57798
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-09
Closed date
2012-10-08
Last modified date
2012-10-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R801 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
08 October 2012