IBM Support

PM56643: QMF RU ABBREVIATION SYNONYM STOPS WORKING AFTER PM45914/UK74603 12/01/24 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • QMF RU abbreviation synonym stops working after PM45914/UK74603
    
    Other keywords:
    
    MESSAGE NUMBER: DSQ20983
    MESSAGE NUMBER: DSQ20115 .... DETECTED ERROR AT
    

Local fix

  • review text of APAR.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All QMF for TSO/CICS V10.1 users who use the *
    *                 'RU' command abbreviation for RUN.           *
    ****************************************************************
    * PROBLEM DESCRIPTION: After applying the fix for PM45914,     *
    *                      users may receive DSQ20115 'RU is not a *
    *                      command.' when executing the RU command *
    *                      abbreviation for RUN.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    PM45914 added a QMF command synonym called 'RUNTSO'. The RUNTSO
    command synonym removed the ability of users to enter the
    command abbreviation 'RU' for the RUN command.  This APAR adds a
    new QMF command synonym 'RU' to the default QMF command synonym
    table to replace the lost RUN command abbrevation.
    

Problem conclusion

  • QMF will add a new command synonym 'RU' that can be used for
    the RUN command as a replacement for the lost command
    abbreviation. Note that QMF generally does not recommend using
    abbreviations for QMF commands, options, or values in saved QMF
    procedures. From the QMF Version 10.1 Reference Guide:  'Because
    minimum unique abbreviations might change in future QMF
    releases, you should use the full names for commands, options,
    and values in procedures (rather than abbreviated names).'
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM56643

  • Reported component name

    QMF-QUERY MGMT

  • Reported component ID

    566872101

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-24

  • Closed date

    2012-04-09

  • Last modified date

    2015-08-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK77781

Modules/Macros

  • DSQ1BLNS DSQ1PTF1
    

Fix information

  • Fixed component name

    QMF-QUERY MGMT

  • Fixed component ID

    566872101

Applicable component levels

  • RA10 PSY UK77781

       UP12/04/11 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: