IBM Support

PM56609: SAMPLE JCL HPSAITKB HAS INCORRECT TABLE NAME

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The sample JCL HPSAITKB provided by APAR PM53934/PTF UK74788
    has an incorrect table name.
    The incorrect line is:
     ADDPROD  PRODUCTID=DA,TABLE=HPSCITKB,REPLACE=YES
    The correct table name is HPSGITKB.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM IMS Database Solution Pack for z/OS      *
    *                 Version 1 Release 2 (FMID=HAHP120)           *
    *                 users who store IMS Tools products reports   *
    *                 in the IMS Tools KB Output repository.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPSAITKB sample jcl has an incorrect    *
    *                      table name in SYSIN,                    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The HPSAITKB is a sample JCL for ITKB products registration.
    This APAR changes the following two issues:
    (1) If you run the JCL, the job ended with RC=04 and the
    following message appears in the SYSPRINT data set,
    because it had incorrect table name.
     HKT2175E External table specified not found in STEPLIB.
     TABLE= HPSCITKB
    
    This APAR corrects the table name.
     (incorrect)  TABLE=HPSCITKB  (correct) TABLE=HPSGITKB
    
    (2) When TABLE= is specified, PRODUCID= is not needed.
    This APAR eliminates the redundant parameters.
    

Problem conclusion

  • HPSAITKB jcl has been modified to fix the errors.
    
    Documentation Changes:
    
    The documentation "IMS Database Solution Pack for z/OS,
    V1R2: Overview and Customization (SC19328400) is changed.
    
    3.6.3 Configuring IMS Tools Knowledge Base
    
     //SYSIN    DD *
    |  ADDPROD  TABLE=BBESITKB,REPLACE=YES
    |  ADDPROD  TABLE=HPSGITKB,REPLACE=YES
    |  ADDPROD  TABLE=FABYTITK,REPLACE=YES
    |  ADDPROD  TABLE=IIUTITKB,REPLACE=YES
    |  ADDPROD  TABLE=FABPITKB,REPLACE=YES
       ADDPROD  PRODUCTID=DU,RELEASE=010200,REPLACE=YES
       ADDPROD  PRODUCTID=DL,RELEASE=020100,REPLACE=YES
       ADDPROD  PRODUCTID=DI,RELEASE=040200,REPLACE=YES
       LIST PRODUCTID=*,REPORTID=*
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM56609

  • Reported component name

    IM DB SOLUTION

  • Reported component ID

    5655S7700

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-01-24

  • Closed date

    2012-02-14

  • Last modified date

    2012-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK76180

Modules/Macros

  • HPSAITKB
    

Publications Referenced
SC19328400    

Fix information

  • Fixed component name

    IM DB SOLUTION

  • Fixed component ID

    5655S7700

Applicable component levels

  • R120 PSY UK76180

       UP12/02/15 P F202 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV358","label":"IMS Database Solution Pack"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date:
23 October 2020