IBM Support

PM56362: Creating fully labeled baseline in Project Explorer: main window title bar reads 'Not responding'

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When creating a fully labeled baseline in IBM Rational ClearCase
    Project Explorer, you may see 'Not responding' in the main title
    bar.  Project Explorer then hangs and is unusable.
    
    This occurs when there are many foundation baselines which are
    not mastered locally.
    
    Workaround:
    
    To resolve the issue, you can do one of the following:
    
    1) Use the command line 'cleartool mkbl'
    
    2) Create the baseline as incrementally labeled and use the
    command line to upgrade to fully labeled  'cleartool chbl'
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Creating fully labeled baseline in Project Explorer : main
    window title bar reads "Not responding"
    

Problem conclusion

  • A fix is available in ClearCase versions 7.1.1.9, 7.1.2.6
    and 8.0.0.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM56362

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-19

  • Closed date

    2012-04-05

  • Last modified date

    2012-05-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R712 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: