Error description
When all the following conditions are met, the partitioned object is not properly triggered. * 1) Objects are at the ALL level. 2) There is at least one Exception condition that is NOT a DB2 CATALOG, MVS CATALOG, and/or REAL TIME STATISTIC exception condition, such as OBJECT PARTITION, SYSCOPY, DB2 DISPLAY, etc. 3) There is at least one Exception condition that IS a DB2 MVS CATALOG and/or REAL TIME STATISTICS Exception Condition, such as MVS CATALOG ALLOCATED_TRACKS. 4) Only ONE object for a partitioned object meets the #3 Exception Condition.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: When all the following conditions are * * met, the partitioned object is not * * properly triggered. * * 1. Objects are at the ALL level. * * 2. There is at least one Exception * * condition that is NOT a DB2 CATALOG, * * MVS CATALOG, and/or REAL TIME * * STATISTIC exception condition, such * * as OBJECT PARTITION, SYSCOPY, DB2 * * DISPLAY, etc. * * 3. There is at least one Exception * * condition that IS a DB2 MVS CATALOG * * and/or REAL TIME STATISTICS Exception * * Condition, such as MVS CATALOG * * ALLOCATED_TRACKS. * * 4. Only ONE object for a partitioned * * object meets the #3 Exception * * Condition. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM56073
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-16
Closed date
2012-02-27
Last modified date
2012-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PM56079 UK76607
Modules/Macros
HAA$BULD HAA$BULJ HAA$BUTH HAA$BUTS HAA$CALL HAA$EXCP HAA$EXPF HAA$IMPF HAA$OINC HAA$OPRI HAA$OPRU HAA$OPVE HAA$OPVL HAA$OXLT HAA#ECDS HAA#EDSP HAA#OBEX HAA#OPRI HAAM51 HAAM518E
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R310 PSY UK76607
UP12/03/03 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
12 February 2021