Error description
Enable the specification of the BLDLPCK statement as an installation default option for IPR.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Unload for * * z/OS Version 1 Release 2 (FMID=H1IN120), who * * use the IPR Unload utility of IMS Database * * Reorganization Expert for z/OS Version 4 * * Release 1 (FMID=H25N410). * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables the specification of * * the BLDLPCK statement as an * * installation default option for IPR. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR enables the specification of the BLDLPCK statement as an installation default option for IPR. To use the new function, the following maintenance is required: - APAR PM55891 for IMS Database Reorganization Expert (FMID=H25N410) This APAR also fixes the ABEND0C4 problem of IPR Unload utility. The ABEND0C4 could occur when all of the following conditions are met: - Type-A user exit is used. - YES is specified as the first user exit option (builds the concatenated key). - The concatenated key length is greater than 256 bytes.
Problem conclusion
Temporary fix
Comments
HP Unload has been modified to support the BLDLPCK statement as an installation default option for IPR.
APAR Information
APAR number
PM55889
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
120
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2012-01-12
Closed date
2012-02-13
Last modified date
2012-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK76174
Modules/Macros
FABHRTI0 HPSUMAIN HPSURPAR HPSUSTMT HPSUURGA HPSUURGB HPSUURG2 HPSUURG8 HPSUURG9 HPSUUXAI HPSU015
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R120 PSY UK76174
UP12/02/15 P F202
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date:
20 October 2020