IBM Support

PM55799: ABEND0C4 IN GLXIINTC + X'C90'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend0c4 in GLXIINTC + x'C90'
    220C90. AREA(Subpool251Key07)+0C90 IN PRIVATE
    220C90. GLXIINTC+0C90 IN PRIVATE
     Failing instruction:     95033001
    R3 = 0890. STRUCTURE(Psa)+0890 IN PSA   0890. IEAVFX00+0890 IN
    PSA     R3 appears to be wrong..
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Generic Exits users                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: abend0c4 in GLXIINTX due to bad logger  *
    *                      parmlist pointer                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    abend0c4 in GLXIINTX due to addressability  to the logger
    exit's parm list was lost
    

Problem conclusion

  • Code was changed to correctly pick up the parmlist address
    Generic MSC exit GEXMSCE0 was also changed to return to IMS
    sooner if it calls itself (user error) and use IMODULE
    DELETE to free GEXISTW
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM55799

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-01-11

  • Closed date

    2012-02-06

  • Last modified date

    2012-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK75986 UK75987

Modules/Macros

  •    GEXIMSCA GEXIMSCB GEXIMSCC GEXMSCE0 GLXIINTA
    GLXIINTB GLXIINTC
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R110 PSY UK75986

       UP12/02/09 P F202

  • R120 PSY UK75987

       UP12/02/09 P F202

  • R130 PSY UK75988

       UP12/02/10 P F202

Fix is available