Error description

  • This APAR addresses the following problems of the DB Sensor:
    - DB_UNUSED_BYTES and DBX_UNUSED_BYTES do not contain the
    recent value for online VSAM KSDS even if TOSIXCFGRP is
    specified
     - DB_NUM_FSE_MIN has incorrect value when the database is
    HISAM.
     - Average Database Record length that reported in the HD
    Pointer Checker DATABASE RECORD STATISTICS is different from
    DB_AVG_DBREC_LENGTH.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM IMS High Performance Pointer Checker for *
    *                 z/OS Version 3 Release 1 (FMID=HPC2310)      *
    *                 users who run HD Pointer Checker (HDPC).     *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR addresses the following       *
    *                      problems of the Database Sensor:        *
    *                      - DB_NUM_FSE_MIN and                    *
    *                        DB_AVG_NUM_NOREUSE_FSE                *
    *                        have incorrect values.                *
    *                      - Average Database Record length        *
    *                       that reported in the HD Pointer        *
    *                       Checker DATABASE RECORD                *
    *                       STATISTICS is different from           *
    *                       DB_AVG_DBREC_LENGTH.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the the following errors:
    
    1. DB_NUM_FSE_MIN has incorrect value.
    
     When SENSOR=YES is specified to the PROCCTL data set,
     Database Sensor runs in HDPC job and it generates Sensor data.
     However, DB_NUM_FSE_MIN and DB_AVG_NUM_NOREUSE_FSE values were
     incorrect. This APAR fixes the values.
    
    2. Average Database Record length that reported in the
     HDPC DATABASE RECORD STATISTICS is different from
     the Sensor data DB_AVG_DBREC_LENGTH. This is because DB Sensor
     includes the padding area in the database record length.
     The padding area is added by IMS to adjust the segment length
     to even value. This difference is confusable.
     To resolve this issue, HD Pointer Checker adds a new
     information
     "AVERAGE DB RECORD LENGTH INCLUDING SEGMENT PAD"
     in the HDPC reports that are
     "Partition Statistics report" and "Database Statistics
     report".
     The report changes are always effective after this APAR
     regardless the DB Sensor is used or not.
    
     APAR dependency
     If you specify SENSOR=YES to the PROCCTL statement,
    it is required to apply APAR PM55789 for IMS Database
    Reorganization Expert for z/OS Version 4 Release 1
    (FMID=H25N410).
    
     Migration consideration
     This APAR changes the internal layout of DBDEFCTL data set.
     Ths DBDEFCTL is used for IMS HP Image Copy Multiple-step HASH
     Check option.
     The old format of DBDEFCTL can be used after this APAR.
     It is not required to regenerate the DBDEFCTL.
    

Problem conclusion

  • The following modules and macros have been modified to fix
    the errors:
    
    FABGORGT FABKCOLL FABPACCP FABPACKE FABPACTL FABPADBS FABPAHIT
    FABPALLC FABPANAL FABPAOPS FABPAPRS FABPARCK FABPARPS FABPASPM
    FABPAWDS FABPBCTL FABPCMP2 FABPDBS0 FABPDCT  FABPDDST FABPECTL
    FABPESTM FABPE35E FABPGET1 FABPHAPI FABPHCTL FABPHEVL FABPHEVS
    FABPHEXM FABPHEXS FABPHINI FABPHPSD FABPHPUT FABPHRCK FABPHSDA
    FABPHSHI FABPHSIX FABPHTRM FABPLBLD FABPLBLX FABPMAIN FABPMSGT
    FABPMSUM FABPOPEX FABPOUT1 FABPPCTL FABPPILE FABPPMAP FABPPSDA
    FABPPSIX FABPRDEF FABPRORG FABPSCMP FABPSCTL FABPSDA0 FABPSEND
    FABPSHI0 FABPSIT  FABPSIX0 FABPSNAP FABPSSUP FABPSTAP FABPSTE0
    FABPSUMM FABPTGEN FABPUCB0 FABPUCDD FABPUCMP FABPUDBR FABPUDB1
    FABPUDCT FABPUDET FABPUDSR FABPUDTB FABPUGET FABPUHDR FABPUHTC
    FABPUMAI FABPUMAP FABPUPHR FABPURND FABPURTO FABPUSPM FABPVCB
    FABPXCTL FABPXPHR FABPXRCK
    
    Documentation Changes:
    Note: The section numbers are those of the BookManager (BKMGR)
    book.
    The documentation is modified as follows:
    ==============================================================
      IMS High Performance Pointer Checker for z/OS, V3R1,
      User's Guide (SC19240101)
    ==============================================================
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    2.0        HD Pointer Checker
    >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
    --------------------------------------------------------------
    2.2         Operating instructions for the HD Pointer Checker
                processor
    2.2.3       Output
    2.2.3.4     STATIPRT data set
    2.2.3.4.15  Partition Statistics report and Database Statistics
                report
    --------------------------------------------------------------
    The following description is added:
    
       AVERAGE DB RECORD PREFIX LENGTH
           The average lengths of prefixes in database records.
    
    |  AVERAGE DB RECORD LENGTH INCLUDING SEGMENT PAD
    |      The average lengths of database records.
    |      Prefix parts, data parts and padding area of all segment
    |      types are included.
    
    Figure 42 reports will be modified as follows:
    
                             AVERAGE DB RECORD LENGTH =        795.8
                      AVERAGE DB RECORD PREFIX LENGTH =        208.1
    |  AVERAGE DB RECORD LENGTH INCLUDING SEGMENT PAD =        810.3
    

Temporary fix

Comments

  • ×**** PE12/03/12 PTF IN ERROR. SEE APAR PM60254  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PM55790

  • Reported component name

    IMS POINTER CHE

  • Reported component ID

    5655E0900

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-01-11

  • Closed date

    2012-02-13

  • Last modified date

    2012-03-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK76118

Modules/Macros

  • FABGORGT FABKCOLL FABPACCP FABPACKE FABPACTL
    FABPADBS FABPAHIT FABPALLC FABPANAL FABPAOPS FABPAPRS FABPARCK
    FABPARPS FABPASPM FABPAWDS FABPBCTL FABPCMP2 FABPDBS0 FABPDDST
    FABPECTL FABPESTM FABPE35E FABPGET1 FABPHAPI FABPHCTL FABPHEVL
    FABPHEVS FABPHEXM FABPHEXS FABPHINI FABPHPSD FABPHPUT FABPHRCK
    FABPHSDA FABPHSHI FABPHSIX FABPHTRM FABPLBLD FABPLBLX FABPMAIN
    FABPMSGT FABPMSUM FABPOPEX FABPOUT1 FABPPCTL FABPPILE FABPPMAP
    FABPPSDA FABPPSIX FABPRDEF FABPRORG FABPSCMP FABPSCTL FABPSDA0
    FABPSEND FABPSHI0 FABPSIX0 FABPSNAP FABPSSUP FABPSTAP FABPSTE0
    FABPSUMM FABPTGEN FABPUCB0 FABPUCDD FABPUCMP FABPUDBR FABPUDB1
    FABPUDCT FABPUDET FABPUDSR FABPUDTB FABPUGET FABPUHDR FABPUHTC
    FABPUMAI FABPUMAP FABPUPHR FABPURND FABPURTO FABPUSPM FABPVCB
    FABPXCTL FABPXPHR FABPXRCK
    

Publications Referenced
SC19240101    

Fix information

  • Fixed component name

    IMS POINTER CHE

  • Fixed component ID

    5655E0900

Applicable component levels

  • R310 PSY UK76118

       UP12/02/14 P F202

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 March 2012