A fix is available
APAR status
Closed as program error.
Error description
Upgrade OMEG XE for DB2 PE to v5.1.0 from v4.2.0 and attempt to run D2#3. It's failing due to a conflicting LRECL sizes in STEP3. IEC141I 013-EC, IGG0191A, D2#3INST, STEP3, SYSUT1, DA7D, SYSR12, SYS1.TIVOLI.TKO2DATA(KO2USR#P) //STEP3 EXEC PGM=IEBGENER //SYSIN DD DUMMY //SYSPRINT DD SYSOUT=* //SYSUT1 DD DISP=SHR,DCB=(LRECL=6156), // DSN=SYS1.TIVOLI.TKO2DATA(KO2USR#P) //SYSUT2 DD DISP=SHR, // DSN=TIVOLI.OMEG.V410.DVL1.RKO2PROF(O2USER#P) D2#3 job gets ABEND IEF450I D2#3INST STEP3 - ABEND=S013 U0000 REASON=000000EC. SYSUT2 (RKO2PROF in this case) has no bearing on dataset type (it can be a PDS or a PDSE). It's SYSUT1 being a PDSE where IEBGENER fails if TKO2DATA LRECL is different from SYSUT2. If SYSUT1 TKO2DATA is a PDS, and it gets copied to a different LRECL RKO2PROF, whether RKO2PROF is a PDSE or PDS, the IEBGENR step doesn't fail. The PTF will remove the IEBGENER step in ICAT's D2#3 job and provide a new mandatory post-configuration step in the Complete the Configuration. This is the documentation that all customers will go through so they will read this step and can copy the profile to the target library for themselves.
Local fix
For the IEBGENR ABEND S013 exposure, temporarily create a non-PDSE version of TKO2DATA and use the later as the input to the IEBGENR step.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - ICAT * **************************************************************** * PROBLEM DESCRIPTION: D2#3 job may fail in specific * * environments. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: The copy step that was used to copy the default profile #P to RKO2PROF was removed. Instead, the Complete the Configuration was enhanced to provide an additional mandatory step for users to copy the profile accordingly. KEYWORDS: ICAT D2#3 #P Classic Profile
Problem conclusion
PROBLEM CONCLUSION: The copy step that was used to copy the default profile #P to RKO2PROF was removed. Instead, the Complete the Configuration was enhanced to provide an additional mandatory step for users to copy the profile accordingly. KEYWORDS: ICAT D2#3 #P Classic Profile
Temporary fix
Comments
APAR Information
APAR number
PM54467
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-12-15
Closed date
2011-12-29
Last modified date
2012-01-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK75149
Modules/Macros
KD2VERS KD261DC1 KD261SJ4
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK75149
UP11/12/30 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0"}]
Document Information
Modified date:
31 March 2021