PM54467: D2#3 JOB FAILED WITH ABENDS013-EC

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Upgrade OMEG XE for DB2 PE to v5.1.0 from v4.2.0 and attempt to
    run D2#3.  It's failing due to a conflicting LRECL sizes in
    STEP3.
    
    IEC141I 013-EC, IGG0191A, D2#3INST, STEP3, SYSUT1, DA7D, SYSR12,
    SYS1.TIVOLI.TKO2DATA(KO2USR#P)
    
    //STEP3  EXEC PGM=IEBGENER
    //SYSIN    DD DUMMY
    //SYSPRINT DD SYSOUT=*
    //SYSUT1   DD DISP=SHR,DCB=(LRECL=6156),
    //         DSN=SYS1.TIVOLI.TKO2DATA(KO2USR#P)
    //SYSUT2   DD DISP=SHR,
    //         DSN=TIVOLI.OMEG.V410.DVL1.RKO2PROF(O2USER#P)
    
    D2#3 job gets ABEND IEF450I D2#3INST STEP3 - ABEND=S013 U0000
    REASON=000000EC.
    
    SYSUT2 (RKO2PROF in this case) has no bearing on dataset type
    (it can be a PDS or a PDSE).  It's SYSUT1 being a PDSE where
    IEBGENER fails
    if TKO2DATA LRECL is different from SYSUT2.  If SYSUT1 TKO2DATA
    is a PDS, and it gets copied to a different LRECL RKO2PROF,
    whether
    RKO2PROF is a PDSE or PDS, the IEBGENR step doesn't fail.
    
    The PTF will remove the IEBGENER step in ICAT's D2#3 job and
    provide a new mandatory post-configuration step in the Complete
    the Configuration.  This is the documentation that all customers
    will go through so they will read this step and can copy the
    profile to the target library for themselves.
    

Local fix

  • For the IEBGENR ABEND S013 exposure, temporarily create a
    non-PDSE version of TKO2DATA and use the later as the input to
    the IEBGENR step.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - ICAT                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: D2#3 job may fail in specific           *
    *                      environments.                           *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    The copy step that was used to copy the default profile #P to
    RKO2PROF was removed. Instead, the Complete the Configuration
    was enhanced to provide an additional mandatory step for users
    to copy the profile accordingly.
    
    KEYWORDS:
    ICAT D2#3 #P Classic Profile
    

Problem conclusion

  • PROBLEM CONCLUSION:
    The copy step that was used to copy the default profile #P to
    RKO2PROF was removed. Instead, the Complete the Configuration
    was enhanced to provide an additional mandatory step for users
    to copy the profile accordingly.
    
    KEYWORDS:
    ICAT D2#3 #P Classic Profile
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM54467

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-12-15

  • Closed date

    2011-12-29

  • Last modified date

    2012-01-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK75149

Modules/Macros

  •    KD2VERS  KD261DC1 KD261SJ4
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK75149

       UP11/12/30 P F112

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0"}]

Document Information

Modified date:
31 March 2021