IBM Support

PM54293: CORRECT VARIOUS TCZ PANEL AND PROCESSING ISSUES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The following issues have been addressed by this PTF.
    
    20939 DB2 entry status is incorrectly displayed as
          "not required"
    
         DB2 status is incorrectly displayed as "not required"
         when DB2 Parameters are required for customization.
    
    20003 "CCQC000I The product was customized on the selected
          DB2 entries." incorrectly issued
    
         When a TCz enabled product has ALL configuration tasks
         as optional and a user uses defaults and selects a DB2
         to customize the product, TCz says "CCQC000I The product
         was customized on the selected DB2 entries."
         but there are no jobs in the customized job table...
         in this scenario, TCz should display something like:
         "No jobs were customized for the selected DB2 entries"
    
    20065 cursor on wrong field after msg ABP901E issued
    
          This feature allows for products to set the cursor to
          the input field that contains invalid value when
          something goes wrong with the discover process.
          TCz enabled products will need to exploit this feature.
    
    20191 & 20192 Clarify CCQ001E message text to better
          identify the real problem.
    
    20315 incorrect display of common parms in 2 optional tasks
    
          When comomon parameter are defined in 2 required steps
          across 2 optional tasks, they are displayed incorrectly
          as required parameters.
          They should be displayed under task level.
    
    20384 cursor on the wrong field after msg ABP901E
    
          After message ABP901E is displayed, the cursor is
          placed on <Discover EXEC library> input field.
          This is confusing, the cursor should be placed on
          the <DB2 UET v2.1 Options Module name> input field.
    
    20425 DB2 status changed from customized to ready when
          LPAR parm edited
    
          Product Parm and DB2 parm status changed to
          "Ready to Customize" when "Not required" LPAR Parm is
          edited. DB2 Parm status also changes to
          "Ready to Customize" when Product Parm is edited.
          If there are 2 DB2 subsystems and one is "Customized"
          and the other is "Incomplete" and Product parms are
          edited, the "Customized" DB2 does not change to
          "Ready to Customize".
          This confusing behavior has been corrected.
    
    20470 Messaged CCQO061I on panel CCQPDSP reworded
    
          Reworded messaged CCQO061I on the DISCOVER panel to
          reduce confusion.
    
    20496 ISPF main task abend when generating jobs
          TCz will issue a msg if the hlq.*TENU dataset is not
          available rather than the ISPF main task ABEND,
          for example as follows:
    
          ISPF error message:
          *** ISPF Main task abend ***
          ISPF     ENDED DUE TO ERROR+
          READY
          ***
    
          TSO error message:
          System abend code 414, reason code 00000004.
          Abend in host command SELECT or address environment
                                              routine ISPEXEC.
          System abend code 414, reason code 00000004.
          Abend in host command SELECT or address environment
                                                    routine ISPEXEC.
          READY
    
    20800 Required parm that is optional in other steps
    
          On the product parameters panel for
          DB2 Change Accumulation tool (GGC), there is a parameter
          that is under a required Task and Step that is not
          being moved to the Required parameters section at the
          top of the panel, even though the parameter is used in
          several other steps.
    
          These required parms should be under the Required
          parameters section
    
    21026 DISCOVER not working when DISCOVER output data set is
          changed on the DISCOVER panel
    
          RUN command is not working when DISCOVER OUPTU data set
          is changed to a different dataset on the TCz DISCOVER
          panel
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    *                 All users of Tools Customizer of z/OS.       *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    *                      Please refer the APAR text for details. *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • Apply the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM54293

  • Reported component name

    TOOLS CUSTOMIZR

  • Reported component ID

    5655TCZ00

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-12-13

  • Closed date

    2012-04-17

  • Last modified date

    2012-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK78016

Modules/Macros

  •    CCQC03   CCQH00   CCQI25   CCQLCNF  CCQLCST
    CCQLDAD  CCQLDSC  CCQLHLQ  CCQLHME  CCQLPRD  CCQLSET  CCQLWRK
    CCQO06   CCQPDSP  CCQQ00   CCQS02   CCQTCZ   CCQUCAA  CCQUCCQ
    CCQUCST  CCQUDAA  CCQUDBM  CCQUDSC  CCQUEAA  CCQUEDX  CCQUINI
    CCQUISP  CCQUMVL  CCQUPDX  CCQUPRM  CCQUSEQ  CCQUSTR  CCQUTPS
    CCQUTSO
    

Publications Referenced
SC19324002    

Fix information

  • Fixed component name

    TOOLS CUSTOMIZR

  • Fixed component ID

    5655TCZ00

Applicable component levels

  • R110 PSY UK78016

       UP12/04/21 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCTTLL","label":"Tools Customizer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: