A fix is available
APAR status
Closed as program error.
Error description
MSGFABP0001I is surrounded by asterisks for emphasis. This APAR changes one asterisk(*) right after MSGFABP0001I into a blank. After applying this APAR, MSGFABP0001I is issued as follows: FABP0001I ****************************************************** FABP0001I * FABP0001I HD POINTER CHECKER ENDED NORMALLY * FABP0001I * FABP0001I ******************************************************
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run HD Pointer Checker (HDPC). * **************************************************************** * PROBLEM DESCRIPTION: This APAR changes one asterisk(*) right * * after MSGFABP0001I into a blank. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** MSGFABP0001I is surrounded by asterisks for emphasis as follows: FABP0001I****************************************************** FABP0001I * FABP0001I HD POINTER CHECKER ENDED NORMALLY * FABP0001I * FABP0001I****************************************************** This APAR changes one asterisk(*) right after MSGFABP0001I into a blank. After applying this APAR, MSGFABP0001I is issued as follows: FABP0001I ***************************************************** FABP0001I * FABP0001I HD POINTER CHECKER ENDED NORMALLY * FABP0001I * FABP0001I ***************************************************** By this APAR, one asterisk(*) right after not only MSGFABP0001I but also the following HDPC messages is also changed into a blank: << Information messages >> FABP0001I, FABP0005I, FABP1365I, FABP4011I << Warning messages >> FABP1520W << Error messages >> FABP0003E, FABP0004E, FABP3505E, FABP3509E, FABP3510E, FABP3568E FABP3571E, FABP3572E, FABP3573E, FABP3574E, FABP3575E, FABP3576E FABP3577E, FABP3578E, FABP3579E, FABP3580E, FABP3587E, FABP3588E FABP3590E, FABP3600E, FABP3601E, FABP3602E, FABP3603E, FABP3604E FABP3605E, FABP3607E, FABP3609E, FABP3619E, FABP3630E, FABP3631E FABP3633E, FABP3660E, FABP3664E, FABP3665E, FABP3666E, FABP3671E FABP3672E, FABP3673E, FABP3674E, FABP3676E, FABP3677E, FABP3679E FABP3690E, FABP3751E, FABP3752E, FABP3753E, FABP3754E, FABP3755E FABP3756E, FABP3757E, FABP3759E, FABP3760E, FABP3762E, FABP3840E FABP3851E, FABP3852E, FABP3860E, FABP3861E, FABP3862E, FABP3863E FABP3988E, FABP3989E, FABP3990E, FABP3991E, FABP3992E, FABP3993E FABP3994E, FABP3995E, FABP3996E, FABP3997E, FABP3998E, FABP3999E FABP4001E, FABP4002E, FABP4019E, FABP4020E, FABP4030E, FABP4031E FABP4032E, FABP4033E, FABP4034E, FABP4035E, FABP4036E, FABP4037E FABP4038E
Problem conclusion
Documentation Changes: Note: The section numbers are those of the BookManager (BKMGR) book. The documentation is modified as follows: ============================================================== IMS High Performance Pointer Checker for z/OS, V3R1, User's Guide (SC19240101) ============================================================== >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 2.0 HD Pointer Checker >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> -------------------------------------------------------------- 2.2 Operating instructions for the HD Pointer Checker processor 2.2.3 Output 2.2.3.2 Messages to operator 2.2.3.2.2 Format -------------------------------------------------------------- The FABP0001I messages in Figure 20 and Figure 21 is changed as follows: FABP0001I ***************************************************** FABP0001I * FABP0001I HD POINTER CHECKER ENDED NORMALLY * FABP0001I * FABP0001I *****************************************************
Temporary fix
Comments
APAR Information
APAR number
PM54058
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-12-12
Closed date
2011-12-15
Last modified date
2012-01-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK74888
Modules/Macros
FABPMSGS
| SC19240101 |
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UK74888
UP11/12/17 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 January 2012