APAR status
Closed as program error.
Error description
When processing 5010X220A1 (834) data with the HIPAA 4.3.2.1 Compliance Check map, if the data contains a N1 segment with a N101 value of TV, the Compliance Check map is not rejecting the data if N102 is absent.
Local fix
WTXCQ - WTX00039401 TR / TR Circumvention: None
Problem summary
Users affected: Websphere Transformation Extender Pack for HIPAA Problem Description: Compliance Check is not rejecting 834 data when the N102 value is missing when N101 is set to TV Platforms Affected: ALL
Problem conclusion
The 1000C N102 is mandatory in the 5010X220A1 834 transaction. hipaa_x12_segment.mtt modified to enforce presence. Delivered in HCIP 4.3.2.1 and future HIPAA pack
Temporary fix
Comments
APAR Information
APAR number
PM52175
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-11-14
Closed date
2011-11-22
Last modified date
2012-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
R440 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: