Error description

  • The looping through the storage manager routine IPI4QMGR is due
    to a storage request that cannot be satisfied as it has hit VS
    high-water mark and no transactions are being flushed.
    The loop shows at offsets x'37a', x'39a', x'39e', x'3a2, x'3a6'.
    
    When IMS PA hits VS high-water it must flush incomplete
    transactions thereby freeing storage to create new transaction
    entries. If the transactions consist of a single program-switch
    chain this is flushed only when the switch count wraps (64k). In
    an environment in which storage is constrained the switch count
    will not reach the wrap point, hence no flushing occurs.
    

Local fix

  • A possible local fix is to set the region= parm on the JOB EXEC
    statement to 0M as REGION=0M.  If this is successful or not may
    depend on your system storage configuration.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.2       *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS PA loops through the storage manger *
    *                      routine (IPI4QMGR) with a storage       *
    *                      request that cannot be satisfied as     *
    *                      it has hit VS high-water mark and no    *
    *                      transactions are being flushed.         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When IMS PA hits VS high-water it must flush incomplete
    transactions thereby freeing storage to create new
    transaction entries. If the transactions consist of a
    single program-switch chain this is flushed only when
    the switch count wraps (64k). In an environment in which
    storage is constrained the switch count will not reach
    the wrap point, hence no flushing occurs.
    

Problem conclusion

  • At VS high-water mark processing flush program switch
    chain irrespective of the switch count.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM50424

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-10-19

  • Closed date

    2011-11-07

  • Last modified date

    2011-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK73616

Modules/Macros

  • IPIIPROC IPISAPAR IPI4PROC
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R420 PSY UK73616

       UP11/11/10 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2011