IBM Support

PM49457: IF THE ODMDIR ENVIRONMENT VARIABLE IS NOT SET WHEN CLEARCASE IS STOPPED, THE MVFS SPECDEV WILL NOT UNLOAD

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the ODMDIR environment variable is not set when ClearCase is
    stopped, the MVFS specdev will not unload
    
    
    AIX (All)
    
    
    ClearCase 7.x
    
    
    
    The Problem:
    
       Users of sudo may not have the ODMDIR environment variable
    set.  As a consequence, the MVFS specdev will not unload when
    ClearCase is stopped.  At this point, the system has to be
    rebooted to clear the problem.
    
    
    Workaround:  Use root to stop ClearCase or ?sudo su - root? to
    inherit the ODMDIR environment variable
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If the ODMDIR environment variable is not set when ClearCase
    is stopped, the MVFS specdev will not unload
    
    
    AIX (All)
    
    
    ClearCase 7.x
    
    
    
    The Problem:
    
       Users of sudo may not have the ODMDIR environment
    variable set.  As a consequence, the MVFS specdev will not
    unload when ClearCase is stopped.  At this point, the system
    has to be rebooted to clear the problem.
    
    
    Workaround:  Use root to stop ClearCase or ?sudo su - root?
    to inherit the ODMDIR environment variable
    

Problem conclusion

  • A fix is available in ClearCase versions 7.1.1.8, 7.1.2.5
    and 8.0.0.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM49457

  • Reported component name

    CC&CC MSITE UNI

  • Reported component ID

    5724G3301

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-06

  • Closed date

    2011-12-16

  • Last modified date

    2011-12-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CC&CC MSITE UNI

  • Fixed component ID

    5724G3301

Applicable component levels

  • R712 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH3S","label":"Rational ClearCase MultiSite"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.2","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]