IBM Support

PM48549: CEX BATCH COMMAND UTILITY FAILS WITH COMMAND SYNTAX ERROR WHEN SEQUENCE NUMBERS ARE PRESENT IN COLUMNS 73-80

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR will address the following:
    - Syntax error from Cex Batch Command utility when sequence
      numbers are present in columns 73-80.
    - MSGCEX5019 issued stating active session cache is full
      without receiving subsequent CEX5019 message saying full cache
      problem was relieved.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extentions V2.2         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Syntax error from Cex Batch Command     *
    *                      utility when sequence numbers are       *
    *                      present in columns 73-80.               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is addressing the following issues:
    1. CEX Batch Command Utility fails with command syntax error
    when data, e.g., sequence numbers, is present in columns
    73-80.
    2. Message CEX5019 issued stating active session cache is
    full without receiving subsequent CEX5019 message saying
    full cache problem was relieved.
    3. Event record x'3E' has incorrect value in field
    CERE_3E_PFXLL when the message exit is HWSMSCX0 and
    the exit was called for READ.
    The value in PFXLL is x'94' and it should be x'14'.
    

Problem conclusion

  • The following changes have been made for the above issues:
    1. CEX Batch Command Utility changed to ignore all data
    in command input in columns 73-80.
    2. Changes made to correctly decrement active session
    cache counter so that subsequent CEX5019 message will
    be issued when full cache problem is relieved.
    3. Correct CEXTECL to not overlay the CERE_3E_PFXLL field
    during event record build.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM48549

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-09-22

  • Closed date

    2011-10-20

  • Last modified date

    2011-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK73105

Modules/Macros

  • CEXBCMD1 CEXEVT01 CEXEXRTR CEXTECL  CEXVUSER
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R220 PSY UK73105

       UP11/10/25 P F110

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
22 October 2020