Error description
PSB schedule requests frsm a CCTL not using the DRA Open Thread option result in unfavorable issues. The issues observed: Return code 32 (RC32), thread is already scheduled. Return code 44 (RC44), invalid call token (paplctkn). Return code 211 (RC211), the recovery token is not unique. CCTL threads hung following a schedule request. These issues apply to CCTL users that are not employing DRA Open Thread option introduced in IMS V12. CICS TS 4.1 or lower users are affected.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V12 CCTL DRA users including: * * - CICS 4.1 and lower users * * - ODBM users that specify RRS=N * **************************************************************** * PROBLEM DESCRIPTION: Multiple symptoms include: * * * * 1. Threads hung in a schedule * * request * * 2. Threads receive RC32 * * 3. Threads receive RC44 * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** 1. DFSPRRA0 uses the wrong ecb pointer to post the waiting request. 2. DFSPRRC0 does not set the thread block pointer (PATE) after having the thread block assigned then fails with RC20 when the thread token is not unique.
Problem conclusion
GEN: KEYWORDS: *** END IMS KEYWORDS *** DFSPRRC0 sets the thread block pointer (PATE) after waiting and clears paploecb only if Open Thread TCB is active. This results in schedule requests being processed correctly. DFSPRRA0, DFSPRA30, DFSFPRA0 have been modified to use the PAPLOECB ecb for open thread path.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM47327
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
200
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-09-07
Closed date
2011-10-20
Last modified date
2014-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
010PC2 UK73103
Modules/Macros
DFSFPRA0 DFSPAPL DFSPRA30 DFSPRRA0 DFSPRRC0
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300