IBM Support

PM46971: TPV SHOWS NEGATIVE VALUES FOR ACTIVECOUNT WHEN ENABLED AT RUNTIM E

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Performance Monitoring Infrastructure (PMI) counter activeCount
    shows negative values on Tivoli Performance Viewer (TPV).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.0                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When PMI counter activeCount is         *
    *                      enabled at runtime in some scenerios    *
    *                      the activeCount shows negative Values   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Whenever the activeCount PMI counter is enabled after server
    startup, in some scenerios the active count shows negative
    values. This is due to the fact that active count was not
    getting tracked until it was enabled. The trigger to update
    the active count will be fired by the thread pool. So once the
    server starts up, the thread pool notifies PMI for updates of
    the activeCount. Since activeCounter is not enabled the update
    does not happen. Ater some time when the activeCount is
    enabled, then it starts updating the counter based on the
    triggers recieved by the threadPool. So in some scenerios when
    the thread pool requests to reduce the counter and at the same
    time activeCount is enabled, it gets reduced and moves into
    negative values.
    

Problem conclusion

  • The reported problem has been fixed by making sure that the
    activeCount datatype is properly tracked irrespective of
    when it was enabled. This makes sure that the negative values
    are avoided.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 8.0.0.2.  Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM46971

  • Reported component name

    WEBSPHERE APP S

  • Reported component ID

    5724J0800

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-02

  • Closed date

    2011-10-26

  • Last modified date

    2011-10-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE APP S

  • Fixed component ID

    5724J0800

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]