Error description
User application using HP Unload API gets into long-wait when GU calls are issued to HALDB.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Unload * * for z/OS Version 1 Release 2 (FMID=H1IN120). * **************************************************************** * PROBLEM DESCRIPTION: User application using HP Unload API * * gets into long-wait when HSSR calls * * are issued to HALDB. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** User application using HP Unload API gets into long-wait, when the HSSR GU calls are issued to HALDB. Internally, BSAM CHECK macros are issued twice erroneously without an intervening READ macro at changing the target partition.
Problem conclusion
The internal cause is that the BSAM CHECK macro is issued but an IO pointer (HDMCIO) is not cleared correctly for an overlapped I/O when the following request is for another partition's blocks. For the IO pointer, the CHECK macro is issued again. The modules FABHA02 and FABHA03 are modified as to clear the IO pointer correctly.
Temporary fix
Comments
APAR Information
APAR number
PM46093
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-08-19
Closed date
2011-08-30
Last modified date
2011-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK71369
Modules/Macros
FABHA20 FABHA30 FABHMAC HLEV
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R120 PSY UK71369
UP11/08/31 P F108