APAR status
Closed as program error.
Error description
Based on the HIPAA ERRATA changes for the 270/271, the first position for the TRN03 value is not required to be 1,3 or 9 in either the 2100C or 2100D loop. The current design of the WTX HIPAA trees for the TRN03 item only allows a 1, 3 or 9 in the first position.
Local fix
WTXCQ - WTX00038461 TR / BD Circumvention: None
Problem summary
Users affected: Websphere Transformation Extender Pack for HIPAA Problem Description: TRN03 does not have to start w/ 1, 3 or 9 for 271 Platforms Affected: ALL
Problem conclusion
RFI #1272 indicated that although the TR3s left the wording in their documentation indicating that in the 271 transaction the left most digit of the TRN03 must be 1, 3 or 9 - the intent was not to enforce it, so we have removed it from the trees. Delivered in HCIP 4.3.2.1 and future HIPAA pack
Temporary fix
Comments
APAR Information
APAR number
PM45987
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
431
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-08-18
Closed date
2011-10-18
Last modified date
2012-02-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
R440 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
03 February 2012