A fix is available
APAR status
Closed as program error.
Error description
In DB2 Object Comparison Tool for z/OS, comparison on multiple tablespaces could result in message: IBM0361W ONCODE=350 The STRINGRANGE condition was raised. From entry point BUILD_LIMITKEY at statement 18715 at compile unit offset +00027FAA at entry offset +00027FAA at address 341F164E. From entry point COMPARE_TABLES at statement 6961 at compile unit offset +00027E20 at entry offset +00027E20 at address 34250D5A. Additional symptoms: oncode350
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of the DB2 Object Comparison Tool for * * z/OS who compare two tables or two indexes * * when specifying IGNORE fields related to * * the PARTITIONING generic IGNORE * * specification, and at least one of the * * compare objects is partitioned. * **************************************************************** * PROBLEM DESCRIPTION: In DB2 Object Comparison Tool for z/OS, * * when comparing two tables and at least * * one of them is partitioned, if some * * but not all IGNORE fields are specified * * and related to the PARTITIONING * * generic IGNORE specification, there * * are several ONCODE=350 / ONCODE350 * * warning messages in the compare job * * log: * * * * IBM0361W ONCODE=350 * * The STRINGRANGE condition was raised. * * * * When comparing two indexes and at least * * one of them is partitioned, if some but * * not all IGNORE fields are specified and * * related to the PARTITIONING generic * * IGNORE specification, the compare job * * failed with a RC=12 and the following * * error messages are in the job log: * * * * No sysindexpart row found for * * Create index. * **************************************************************** * RECOMMENDATION: * **************************************************************** In DB2 Object Comparison Tool for z/OS, when comparing two tables and at least one of them is partitioned, if some but not all IGNORE fields are specified and related to the PARTITIONING generic IGNORE specification, there are several ONCODE=350 / ONCODE350 warning messages in the compare job log: IBM0361W ONCODE=350 The STRINGRANGE condition was raised. When comparing two indexes and at least one of them is partitioned, if some but not all IGNORE fields are specified and related to the PARTITIONING generic IGNORE specification, the compare job failed with a RC=12 and the following error messages are in the job log: No sysindexpart row found for Create index. ADBC002E - Severe error. Compare terminates. ADB0380E Module ADB2CMP - Severe error Compare terminates.
Problem conclusion
Problem has been resolved and a new message has been added to warn users when they specify some but not all fields relating to generic partitioning: (W)Some but not all fields related to partitioning have been ignored. This may lead to unpredictable results. Please use generic ignore PARTITIONING if you want to IGNORE partition information during compare, otherwise please remove all ignore fields related to partitioning which have been specified.
Temporary fix
Comments
APAR Information
APAR number
PM45471
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-10
Closed date
2011-12-08
Last modified date
2012-01-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
GOC2CMF GOC2CMP GOC2CMR GOC2CMT GOC2IGN
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK74610
UP11/12/13 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]