APAR status
Closed as program error.
Error description
HIPAA 837 data file does not fail compliance check when both 2330B Claim Check or Remittance Date and 2430 Line Check or Remittance Date are present. Page 389 of the 005010X223 implementation guide states: Required when the payer identified in this loop has previously adjudicated the claim and Loop ID-2430, Line Check or Remittance Date, is not used. If not required by this implementation guide, do not send. Suggesting that these segments are mutually exclusive.
Local fix
WTXCQ - WTX00038326 YQ / YQ Circumvention: None
Problem summary
Users affected: WebSphere Transformation Extender Pack for HIPAA Problem Description: 837 - When DTP01 = 573 at both 2330B and 2430 Loops, File is being acepted instead of rejecting Platforms affected: ALL
Problem conclusion
Added Rules 35101, 35102, 35103 to qualifier file and master tree. Delivered in HCIP 4.3.2.1
Temporary fix
Comments
APAR Information
APAR number
PM45235
Reported component name
WEBSPHERE HIPAA
Reported component ID
5724M6100
Reported release
431
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-08-08
Closed date
2011-08-22
Last modified date
2012-02-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE HIPAA
Fixed component ID
5724M6100
Applicable component levels
R431 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
10 February 2012