IBM Support

PM45024: ABEND052 RC102 CQMISMPX+12546

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND052 can occur when maintenance is applied involving a
    recycle of the Master Address Space (CQMMSTR). LPA resident
    module CQM#CQMA will not be refreshed after a MASTER recycle
    unless some    intervening operator commands are entered
    
    Code is being added to remove the LPA requirement for CQM#CQMA
    from the CQMMSTR initialization process and allow maintenance to
    be applied without the need for intervening operator commands
    

Local fix

  • Workaround option 1:
    
    Schedule CQM maintenance to coincide with a system IPL to ensure
    LPA is refreshed at IPL time.
    
    Workaround option 2:
    
    Alternatively, the following steps can be used after CQM
    maintenance has been applied to eliminate the S052 ABENDS:
    
    1.Stop CQMMSTR Note:
    
    The recommended procedure for stopping the
    CQMMSTR (after all instances of Query Monitor and Audit
    Management Expert running on the MVS image have been stopped),
    is to start CQM with PARM=.SM,MSTOP. (refer to SCQMSAMP member
    CQMMSTR for an example of the "SM,MSTOP" parameters). This will
    ensure an orderly cleanup of the shared memory allocation and
    termination of the CQMMSTR address space. If customer is only
    running Query Monitor, the CQMMSTR still needs to cycled.
    
    2. Issue SETPROG LPA,DELETE,MODNAME=(CQM#CQMA),FORCE=YES
    repeatedly until following message is seen:
    
    CSV551I 18.21.04 LPA DELETE 302
    SUCCESSFUL: 0 UNSUCCESSFUL: 1 NOT PROCESSED:
    0 MODULE RESULT
    CQM#CQMA NOT SUCCESSFUL. NOT IN DYNAMIC LPA
    
    3. Issue SETPROG LPA,DELETE,MODNAME=(CQM#CQMI),FORCE=YES
    repeatedly until following message is seen:
    
    CSV551I 18.21.04 LPA DELETE 302
    SUCCESSFUL: 0 UNSUCCESSFUL: 1 NOT PROCESSED: 0
    MODULE RESULT
    CQM#CQMI NOT SUCCESSFUL. NOT IN DYNAMIC LPA
    
    4. Start CQM
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND052 can occur when maintenance is  *
    *                      applied involving a recycle of the      *
    *                      Master Address Space (CQMMSTR). LPA     *
    *                      resident module CQM#CQMA will not be    *
    *                      refreshed after a MASTER recycle        *
    *                      unless some intervening operator        *
    *                      commands are entered. Code is being     *
    *                      added to remove the LPA requirement     *
    *                      for CQM#CQMA from the CQMMSTR           *
    *                      initialization process and allow        *
    *                      maintenance to be applied without the   *
    *                      need for intervening operator           *
    *                      commands.                               *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM45024

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-08-03

  • Closed date

    2011-09-01

  • Last modified date

    2011-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    CQM@WDB2
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UK71565

       UP11/09/16 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
17 March 2021