A fix is available
APAR status
Closed as new function.
Error description
This APAR enables storing several reports of HP Prefix Resolution to the output repository of ITKB.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Prefix Resolution * * for z/OS Version 3 Release 1 users * * (FMID=H1IP310). * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables to store several * * reports of IMS HP Prefix Resolution in * * the Output repository of IMS Tools * * Knowledge Base. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR enables to store several reports of IMS HP Prefix Resolution in the Output repository of IMS Tools Knowledge Base. The ITKBLOAD and ITKBSRVR control statements of the IMS HP Prefix Resolution FABYIN dataset are added to communicate to the IMS Tools Knowledge Base server. ITKBLOAD specifies the name of the load module library for IMS Tools Knowledge Base. ITKBSRVR specifies the name of the IMS Tools Knowledge Base server. The default value of the ITKBSRVR and ITKBLOAD control statements can be changed with site default options. The following reports of IMS HP Prefix Resolution can be stored in the Output repository of IMS Tools Knowledge Base: - FABYIN Control Statements report - Statistics report - Update Processing Summary report To store the reports in the Output repository of IMS Tools Knowledge Base, you need to set up the environment with the following steps: 1. Install the IBM IMS Tools Knowledge Base product. 2. Set up an IMS Tools Knowledge Base server. 3. Register IMS HP Prefix Resolution to the registry of the IMS Tools Knowledge Base server by running the following job: //DREP EXEC PGM=HKTAPRA0,PARM='ITKBSRVR=srvrname' //STEPLIB DD DISP=SHR,DSN=ITKB.SHKTLOAD ITKB LOAD LIBRARY // DD DISP=SHR, // DSN=HPS.SHPSLMD0 PREFIX RESOLUTION LOAD LIBRARY //SYSPRINT DD SYSOUT=* //SYUDUMP DD SYSOUT=* //SYSIN DD * ADDPROD TABLE=FABYTITK PRODUCTID=DH 4. If needed, add the definitions for the RECON. 5. Confirm that IMS Tools Knowledge Base server is initialized before you run IMS HP Prefix Resolution jobs. 6. Run IMS HP Prefix Resolution jobs with the ITKBSRVR and ITKBLOAD control statements. //FABYIN DD * TYPE=LM UPDATE=YES ITKBSRVR=srvrname ITKBLOAD=ITKB.SHKTLOAD If you do not explicitly specify the ITKBLOAD control statement, IMS HP Prefix Resolution attempts to load an IMS Tools Knowledge Base module from the STEPLIB libraries. After completing these configuration procedures, you can use the ISPF user interface to view, print, and manage reports that are generated by IMS HP Prefix Resolution and that are stored in the IMS Tools Knowledge Base repository.
Problem conclusion
Temporary fix
Comments
======================== = Documentation Change = ======================== IMS High Performance Prefix Resolution for z/OS Version 3 Release 1 User's Guide SC18-9230-02 ( SC18923002 ) should be changed as Update 1 of "Updates to IMS High Performance Prefix Resolution V3.1 User's Guide".
APAR Information
APAR number
PM43488
Reported component name
IMSPREFIXRESOLU
Reported component ID
5655I1500
Reported release
310
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2011-07-11
Closed date
2011-09-13
Last modified date
2011-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK71841
Modules/Macros
FABYDSCT FABYGITB FABYGIT0 FABYGOPT FABYHXP8 FABYINI0 FABYISI0 FABYITMC FABYITMR FABYITMT FABYIT10 FABYIT20 FABYLINK FABYMAIN FABYTE00 FABYTGEN FABYTITK FABYTRM0 FABYUP00 FABYWMT FABYWM0 FABY0040 H1IP310J
| SC18923002 |
Fix information
Fixed component name
IMSPREFIXRESOLU
Fixed component ID
5655I1500
Applicable component levels
R310 PSY UK71841
UP11/09/15 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89H","label":"IMS HP Prefix Resolution"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
21 October 2020