A fix is available
APAR status
Closed as program error.
Error description
TIME OF DAY CLOCK: C7F32D2F 03D00401 06/20/2011 10:53:04.579840 local Symptom Description ------- ----------- RIDS/KO2CDB22#L Load module name: KO2CDB22 RIDS/#UNKNOWN Csect name: #UNKNOWN AB/S00D5 System abend code: 00D5 PRCS/05000302 Abend reason code: 05000302 REGS/0E02A Register/PSW difference for R0E: 02A REGS/0A390 Register/PSW difference for R0A: 390 Time of Error Information PSW: 07758000 80000000 00000000 11236D00 Instruction length: 04 Interrupt code: 0010 Failing instruction text: 00045890 800C59C0 901C4780 Translation exception address: 00000000_509E9002 This PSW points to offset X'9E0' in O2CTHJ (V510510 05/17/11 15:50 PM35122 DB2810) Breaking event address: 00000000_106C684C AR/GR 0-1 00000000/00000000_00000000 00000000/00000000_00000000 AR/GR 2-3 00000000/00000000_00000070 00000000/00000000_40404040 AR/GR 4-5 00000000/00000000_0000005A 00000000/00000000_00000ED8 AR/GR 6-7 00000000/00000000_13662020 00000000/00000000_13662070 AR/GR 8-9 00000000/00000008_009EB968 00000000/00000000_509E9FD8 AR/GR 10-11 00000000/00000000_11236970 00000000/00000000_00000004 AR/GR 12-13 00000000/00000000_C9D5D3D6 00000000/00000000_1287D530 AR/GR 14-15 00000000/00000000_91236CD6 00000000/00000000_00000000 The SYSTRACE shows the following: 02 005A 009C7E88 PGM 010 077D8000 91236D00 00040010 00000000 00000000 00000000 005A 0066 10:53:02.461521 2C 509E9002 00000000 02 005A 009C7E88 *RCVY PROG 840D5000 05000302 00000000 00000000 00000000 005A 0066 10:53:02.461589 2C 00000000 02 005A 009C7E88 SSRV 12D 8151D5B0 009C7E88 000C8000 FF3A0000 Status NDETcb Reset 10:53:02.461616 2C 00000000 02 005A 009C7E88 SSRV 12D 8151D5CC 009C7E88 000B8000 00000000 Status SDETcb Reset 10:53:02.461619 2C 00000000 02 005A 009C7E88 DSP 077D0000 81520518 00000000 00000000 00000000 00000000 00000000 005A 005A 10:53:02.461623 2C 02 005A 009C7E88 *SVC D 077D0000 8152051A 00000000 00000000 00000000 10:53:02.461623 2C R9 is bad, the code is scanning TIOT entries looking at DDNAME This is due to an incorrect ASID (from the previous batch utility) being used, instead of the current batch utility ASID
Local fix
No workaround
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 IN KO2CDB22 CSECT O2CTHJ * * OFFSET X'9E0'AND ABEND0D5, INCORRECT * * ASID WAS USED. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: Batch utility was terminated and ASID had been freed. The attempt to access it caused the ABEND0C4 and ABEND0D5. PROBLEM CONCLUSION: Added check for valid ASID.
Problem conclusion
Added check for valid ASID.
Temporary fix
Comments
APAR Information
APAR number
PM42584
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-06-28
Closed date
2011-07-15
Last modified date
2017-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK69807 UK69808
Modules/Macros
KO2CTHJA KO2CTHJK KO2CTHJS KO2CTHJ2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: