Error description
A return code greater than 4 on a reorg utility can cause a subsequent JCL error. This can occur if an Index reorg follows a tablespace Reorg and runtime statistics are being collected. The JCL error occurs in the HAA#BTMP step following the index reorg because the previous IEBGENER step that produces the SYSPRINT dataset for the HAA#BTMP step is skipped due to return codes. The HAA#BTMP step should also be skipped in this case which would cause the job to end with the appropriate return code instead of the JCL error.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: A return code greater than 4 on a * * reorg utility can cause a subsequent * * JCL error. * * This can occur if an Index reorg * * follows a tablespace Reorg and runtime * * statistics are being collected. * * The JCL error occurs in the HAA#BTMP * * step following the index reorg because * * the previous IEBGENER step that * * produces the SYSPRINT dataset for the * * HAA#BTMP step is skipped due to * * return codes. * * The HAA#BTMP step should also be * * skipped in this case which would * * cause the job to end with the * * appropriate return code instead * * of the JCL error. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Apply the PTF.
Temporary fix
Comments
ž**** PE12/02/10 PTF IN ERROR. SEE APAR PM57607 FOR DESCRIPTION
APAR Information
APAR number
PM42080
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-20
Closed date
2011-12-06
Last modified date
2012-02-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HAA$BMSG
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R310 PSY UK74526
UP11/12/17 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
12 February 2021