Error description
User has a this EGL plrogram: ACCNO num(17); RAC char(34); ACCNO = RAC; The generated cobol (using maxNumericDigits=18) in RBD V7 and V8 fails to compile with the following message: IGZ0151S Argument-1 for function NUMVAL-C in program EI50600 at displacement X'042354' contained more than 18 This worked correctly in V6.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The numvalc COBOL runtime routine was not properly handling ?16 digits and was producing erroneous results. This was only failing when maxNumericDigits was set to 18. When set to 31, which is the normal case, the values are correct.
Problem conclusion
The software now calls the EGL runtime instead to convert the text, for all assignment cases, when maxnumericdigits has been set to 18.
Temporary fix
Comments
APAR Information
APAR number
PM41944
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-17
Closed date
2012-03-15
Last modified date
2012-03-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R751 PSN
UP