Error description

  • Customer receives abendB78-28 in FPEVDB2I because data retrieval
    requests issued from VTAM with user authorization exit enabled
    are not handled correctly.
    .
    OMPE Server joblog shows:
    .
    16.59.55 STC00704  FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
    16.59.55 STC00704  FPEV9999I LVLS/OMEGAMON XE PE/PM
    16.59.55 STC00704  FPEV9999I VALU/SVCE
    16.59.55 STC00704  FPEV9999I AB/S/B78
    16.59.55 STC00704  FPEV9999I AB/U/000
    16.59.55 STC00704  FPEV9999I RIDS/FPEVDB2I#l
    16.59.55 STC00704  FPEV9999I RIDS/ç  ä0  ä
    16.59.55 STC00704  FPEV9999I PTFS/   Fø h 0 gü
    16.59.55 STC00704  FPEV9999I ADRS/N/A
    16.59.55 STC00704  FPEV9999I PSW /070C1000 81548F94
    16.59.55 STC00704  FPEV9999I REGS 0-1/84000000 84B78000
    16.59.55 STC00704  FPEV9999I REGS 2-3/00000448 54000101
    16.59.55 STC00704  FPEV9999I REGS 4-5/0F073200 0F0D5DFA
    16.59.55 STC00704  FPEV9999I REGS 6-7/00000000 10C1D828
    16.59.55 STC00704  FPEV9999I REGS 8-9/00000000 00840001
    16.59.55 STC00704  FPEV9999I REGS A-B/00000448 0EF6C000
    16.59.55 STC00704  FPEV9999I REGS C-D/8F0ECBF0 0F044398
    16.59.55 STC00704  FPEV9999I REGS E-F/0F0ECCCA 00004B28
    16.59.57 STC00704  IEA995I SYMPTOM DUMP OUTPUT  118
        118       SYSTEM COMPLETION CODE=B78  REASON CODE=00004B28
    118       TIME=16.59.55  SEQ=01107  CPU=0040 ASID=0077
        118       PSW AT TIME OF ERROR  070C1000 81548F94  ILC 2  I
        118                NO ACTIVE MODULE FOUND
        118     NAME=UNKNOWN
        118     DATA AT PSW  01548F8E - 00181610 0A0D50E0 81548F94
        118     GR 0: 07851000_84000000   1: 00000000_84B78000
        118        2: 00000000_00000448   3: 00000000_54000101
        118        4: 00000000_0F073200   5: 00000000_0F0D5DFA
        118        6: 00000000_00000000   7: 00000000_10C1D828
        118        8: 00000000_00000000   9: 00000000_00840001
        118        A: 00000000_00000448   B: 00000000_0EF6C000
        118        C: 00000000_8F0ECBF0   D: 00000000_0F044398
        118        E: 00000000_0F0ECCCA   F: 00000000_00004B28
        118              END OF SYMPTOM DUMP
    .
    DUMP Shows:
    .
    Symptom             Description
    --------            ------------
     RIDS/FPEVDB2I#L     Load module name: FPEVDB2I
     RIDS/IGVVSTOR       Csect name: IGVVSTOR
     AB/S0B78            System abend code: 0B78
     PRCS/00004B28       Abend reason code: 00004B28
    .
    PSW=070C1000 81548F94
     (Running in PRIMARY, key 0, AMODE 31, DAT ON)
    DISABLED FOR PER
    ASID(X'008E') 01548F94. IEANUC01.IGVVSTOR+07BC IN READ ONLY NUC
       ASCB142 at FA8580, JOB(OMGO2), for the home ASID
       ASXB142 at AFDDF8 and TCB142M at AC7BF8 for the home ASID
     HOME ASID: 008E PRIMARY ASID: 008E SECONDARY ASID: 008E
    

Local fix

  • Action:
    .
    As work around the user authorization exit of the PE Server
    subtask should be disabled.
    .
    To do so use ICAT to set the corresponding option to NO.
    .
    Enable OMEGAMON Collector user exit   ==> N   (Y, N),
    .
    As an alternative directly edit the configuration parameter
    member OMPEMSTR in data set RKD2PAR of the OMEGAMON runtime and
    set the value of parameter USEUSERAUTHEXIT to NO:
    .
    USEUSERAUTHEXIT=NO
    .
    Then restart the OMEGAMON Collector.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    *                 - Classic Interface                          *
    *                 - Performance Expert Client                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend B78-28 in PE Server subtask load  *
    *                      module FPEVDB2I.                        *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Wrong pointer is used to free the data area returned from the
    user authorization exit.
    
    PROBLEM CONCLUSION:
    Code in CSECT FPEVDB2I has been corrected.
    
    KEYWORDS: FPEVDB2I ABEND B78-28
    

Problem conclusion

  • PROBLEM CONCLUSION:
    Code in CSECT FPEVDB2I has been corrected.
    
    KEYWORDS: FPEVDB2I ABEND B78-28
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM40314

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-05-27

  • Closed date

    2011-06-15

  • Last modified date

    2017-06-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK68789

Modules/Macros

  •    DGOVCRDB DGOVDSS  DGOVMSTR DGOVSADK DGOVSCNT
    DGOVSCON DGOVSDTS DGOVSLOC DGOVSORT FPEMEXA0 FPEVDB2F FPEVDB2I
    FPEVSAD3 FPEVXCMM FPEVZMAI
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK68789

       UP11/06/18 P F106

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 June 2017