A fix is available
APAR status
Closed as program error.
Error description
Customer receives abendB78-28 in FPEVDB2I because data retrieval requests issued from VTAM with user authorization exit enabled are not handled correctly. . OMPE Server joblog shows: . 16.59.55 STC00704 FPEV9999I **** DB2 PM/PE SYMPTOM RECORD **** 16.59.55 STC00704 FPEV9999I LVLS/OMEGAMON XE PE/PM 16.59.55 STC00704 FPEV9999I VALU/SVCE 16.59.55 STC00704 FPEV9999I AB/S/B78 16.59.55 STC00704 FPEV9999I AB/U/000 16.59.55 STC00704 FPEV9999I RIDS/FPEVDB2I#l 16.59.55 STC00704 FPEV9999I RIDS/ç ä0 ä 16.59.55 STC00704 FPEV9999I PTFS/ Fø h 0 gü 16.59.55 STC00704 FPEV9999I ADRS/N/A 16.59.55 STC00704 FPEV9999I PSW /070C1000 81548F94 16.59.55 STC00704 FPEV9999I REGS 0-1/84000000 84B78000 16.59.55 STC00704 FPEV9999I REGS 2-3/00000448 54000101 16.59.55 STC00704 FPEV9999I REGS 4-5/0F073200 0F0D5DFA 16.59.55 STC00704 FPEV9999I REGS 6-7/00000000 10C1D828 16.59.55 STC00704 FPEV9999I REGS 8-9/00000000 00840001 16.59.55 STC00704 FPEV9999I REGS A-B/00000448 0EF6C000 16.59.55 STC00704 FPEV9999I REGS C-D/8F0ECBF0 0F044398 16.59.55 STC00704 FPEV9999I REGS E-F/0F0ECCCA 00004B28 16.59.57 STC00704 IEA995I SYMPTOM DUMP OUTPUT 118 118 SYSTEM COMPLETION CODE=B78 REASON CODE=00004B28 118 TIME=16.59.55 SEQ=01107 CPU=0040 ASID=0077 118 PSW AT TIME OF ERROR 070C1000 81548F94 ILC 2 I 118 NO ACTIVE MODULE FOUND 118 NAME=UNKNOWN 118 DATA AT PSW 01548F8E - 00181610 0A0D50E0 81548F94 118 GR 0: 07851000_84000000 1: 00000000_84B78000 118 2: 00000000_00000448 3: 00000000_54000101 118 4: 00000000_0F073200 5: 00000000_0F0D5DFA 118 6: 00000000_00000000 7: 00000000_10C1D828 118 8: 00000000_00000000 9: 00000000_00840001 118 A: 00000000_00000448 B: 00000000_0EF6C000 118 C: 00000000_8F0ECBF0 D: 00000000_0F044398 118 E: 00000000_0F0ECCCA F: 00000000_00004B28 118 END OF SYMPTOM DUMP . DUMP Shows: . Symptom Description -------- ------------ RIDS/FPEVDB2I#L Load module name: FPEVDB2I RIDS/IGVVSTOR Csect name: IGVVSTOR AB/S0B78 System abend code: 0B78 PRCS/00004B28 Abend reason code: 00004B28 . PSW=070C1000 81548F94 (Running in PRIMARY, key 0, AMODE 31, DAT ON) DISABLED FOR PER ASID(X'008E') 01548F94. IEANUC01.IGVVSTOR+07BC IN READ ONLY NUC ASCB142 at FA8580, JOB(OMGO2), for the home ASID ASXB142 at AFDDF8 and TCB142M at AC7BF8 for the home ASID HOME ASID: 008E PRIMARY ASID: 008E SECONDARY ASID: 008E
Local fix
Action: . As work around the user authorization exit of the PE Server subtask should be disabled. . To do so use ICAT to set the corresponding option to NO. . Enable OMEGAMON Collector user exit ==> N (Y, N), . As an alternative directly edit the configuration parameter member OMPEMSTR in data set RKD2PAR of the OMEGAMON runtime and set the value of parameter USEUSERAUTHEXIT to NO: . USEUSERAUTHEXIT=NO . Then restart the OMEGAMON Collector.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * * - Classic Interface * * - Performance Expert Client * **************************************************************** * PROBLEM DESCRIPTION: Abend B78-28 in PE Server subtask load * * module FPEVDB2I. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Wrong pointer is used to free the data area returned from the user authorization exit. PROBLEM CONCLUSION: Code in CSECT FPEVDB2I has been corrected. KEYWORDS: FPEVDB2I ABEND B78-28
Problem conclusion
PROBLEM CONCLUSION: Code in CSECT FPEVDB2I has been corrected. KEYWORDS: FPEVDB2I ABEND B78-28
Temporary fix
Comments
APAR Information
APAR number
PM40314
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-27
Closed date
2011-06-15
Last modified date
2017-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68789
Modules/Macros
DGOVCRDB DGOVDSS DGOVMSTR DGOVSADK DGOVSCNT DGOVSCON DGOVSDTS DGOVSLOC DGOVSORT FPEMEXA0 FPEVDB2F FPEVDB2I FPEVSAD3 FPEVXCMM FPEVZMAI
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UK68789
UP11/06/18 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: