Error description
IMS DEDB Fast Recovery enhancement to support the following IMS V12 APARs: - PM26393 (PTF is UK62042 ) - PM33361 (PTF is UK66127 ) - PM33270 (PTF is UK68108 ) These are various DFSFDLW0 problems for IMS V12 that need to be addressed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS DEDB FAST RECOVERY Version 2 * * Release 2 (FMID=H1J2220) users in IMS V12. * **************************************************************** * PROBLEM DESCRIPTION: This APAR is DFR version for following * * IMS V12 APARs: * * - PM26393 (PTF is UK62042) * * - PM33361 (PTF is UK66127) * * - PM33270 (PTF is UK68108) * * These are various DFSFDLW0 problems for * * IMS V12 that need to be addressed. * * addressed. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** - PM40201 for IMS DEDB Fast Recovery The following problems under IMS V12 are fixed by this APAR: * 1. IMS V12 PTM to APAR conversion. 2. If it is found that flags for I/O error and end of file are not being initialized between the primary and secondary WADS, causing DFR to skip reading the secondary WADS with a MSGDFR3100E message. 3. If there is an I/O error on a WADS, DFR ends with abend code of S001-04.
Problem conclusion
Temporary fix
Comments
The following module has been modified. * DFRFDLWC - This module was changed as follows: . The block sequence comparison has been changed to use the correct register. . It was changed to retrieve data from both the primary and secondary WADS before rebuilding block and padding the last block. Detection of duplicate data from the secondary WADS has been corrected. . The flags for I/O error and end of file were reset before reading the secondary WADS. . An EADSCB=OK keyword was added to a model for a WADS DCBE. . An EROPT=ACC keyword was added to a model for a WADS DCB. . A SYNAD, EOD and ABEND exits have been correctly set for the both WADSs. * ======================== = DOCUMENTATION CHANGE = ======================== IMS DEDB Fast Recovery for z/OS Version 2 Release 2 User's Guide and Reference (Document Number: SC27-0928-04) should be changed as follows. ================================================================ 8.0 Troubleshooting 8.4 Messages . Descriptions for the following messages have been changed: . DFR3100E xxxxxxxxxxx ERROR IN WADS DDNAME=ddname DFR3100E xxxxxxxxxxx ERROR IN WADS PROCESSING . Explanation: ... . | System action: | If the error occurred on a dual WADS, the job continues | using the alternate data set. | If errors occurred in both WADSs, or the mode is a | single WADS, the job ends with an abend code of U3100. . User Response: | If the job has abnormally ended, check whether DD | statement for WADS is specified correctly. If there is any error, correct it and rerun the job. If there is no error in the DD statement, contact IBM Software Support. *
APAR Information
APAR number
PM40201
Reported component name
DEDB FAST RECOV
Reported component ID
5655E3200
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-26
Closed date
2011-05-26
Last modified date
2011-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68200
Modules/Macros
DFRFDLWC
| SC27092804 |
Fix information
Fixed component name
DEDB FAST RECOV
Fixed component ID
5655E3200
Applicable component levels
R220 PSY UK68200
UP11/05/31 P F105
Fix is available