A fix is available
APAR status
Closed as program error.
Error description
HPIC STACK process updated JFCB for each output data set for writing multiple data sets in one tape. It changed the blocksize in the DCB, but leaving the blocksize in the DCBE alone at OPEN exit. If a DCBE is coded, then the DCBE must be updated to reflect the correct blocksize that will be used.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: HP Image Copy stacking process for * * Image Copy function ends with CC=8 and * * IEC141I 013-20 ( MSGIEC141I RSN20 ) * * message. * * * * HPIC sets multiple of record size for * * the first DBDS into the DCBE of ICDS as * * block size, and it is not overwritten * * with the correct value for subsequence * * DBDS. Therefore, the OPEN process for * * subsequence ICDS fails by using * * inappropriate block size. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Image Copy stacking process for Image Copy function ends with CC=8 and IEC141I 013-20 ( MSGIEC141I RSN20 ) message. HPIC sets multiple of record size for the first DBDS into the DCBE of ICDS as block size, and it is not overwritten with the correct value for subsequence DBDS. Therefore, the OPEN process for subsequence ICDS fails by using inappropriate block size. When the STACK process is used, HP image Copy always uses system optimized block size. When the ICOUT process and its block size is not specified on the DD card of the image copy data set, HP Image Copy uses appropriate calculated vale as the block size.
Problem conclusion
FABJDOPN has been modified as follows: - To set zero in DCBBLKSI and DCBEBLKSI at the QSAM Open exit routine, when the STACK process is selected. - To set zero in the DCBBLKSI at the QSAM Open exit routine, when the ICOUT process is selected and DD cards for image copy data set are not presented. - To set appropriate block size in both DCB and DCBE at the QSAM Open exit, when the ICPUT process is selected and DD cards for image copy data sets are presented. - To use the block size in the DCBE for Open process for the LBI capable tape unit.
Temporary fix
Comments
APAR Information
APAR number
PM39736
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-22
Closed date
2011-06-27
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK69153
Modules/Macros
FABJDOPN
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK69153
UP11/06/28 P F106
Fix is available