Error description
An S878 abend can occur if the DB2 Fetch Buffer Size setup parameter is set too large. This parameter is on the 'Shared Profile Parameters' setup panel. The maximum value allowed on the panel is 2047M. A value near this limit can result in an S878 abend. This APAR will limit the DB2 Fetch Buffer Size setup parm to a value of 256 megabytes or less.
Local fix
Lower the 'DB2 Fetch Buffer Size' parameter on the Setup panel. 10M should be sufficient for this parameter.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: An S878 abend can occur if the DB2 * * Fetch Buffer Size setup parameter is * * set too large. This parameter is on * * the 'Shared Profile Parameters' setup * * panel. The maximum value allowed on * * the panel is 2047M. A value near this * * limit can result in an S878 abend. This * * APAR will limit the DB2 Fetch Buffer * * Size setup parm to a value of 256 * * megabytes or less. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM39221
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-13
Closed date
2011-11-15
Last modified date
2011-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK73876 PM54180
Modules/Macros
HAA$ADM2 HAA$JOVR HAA$JOVV HAAHJOVR HAAHJOVV HAAHLP3 HAAM37 HAAM370E HAAPNL3
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R310 PSY UK73876
UP11/11/18 P F111
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
12 February 2021